{"product_id":"ic670mdl930-field-control-i-o-module-ge-fanuc","title":"IC670MDL930 Field Control I\/O Module GE Fanuc","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC670MDL930\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC670MDL930\u003c\/strong\u003e Relay Output Module, operates as a dedicated hardware component for driving AC and DC field loads within Field Control I\/O station platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e132 mm x 45 mm x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e313 mA (from BIU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Total (6x Form A, 2x Form C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e5\/24\/125 VDC, 120\/240 VAC (47-63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current\u003c\/td\u003e\n\u003ctd\u003e2 A per point (5-265 VAC \/ 5-30 VDC), 0.2 A per point (31-125 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 10 ms (ON), \u0026lt;= 10 ms (OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the Field Control Bus Interface Unit (BIU) to manage discrete output states. In high-density automation architectures, firmware flash compatibility and backplane bus communication velocity are critical for ensuring deterministic signal propagation. The IC670MDL930 leverages standard Field Control backplane mechanics to maintain synchronization across the station, facilitating rapid I\/O density scaling. The absence of internal fuses necessitates external circuit protection planning to mitigate surge currents and maintain backplane operational integrity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support hot-swapping during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Field Control modules are designed for integration with the Field Control I\/O base. While the base supports module extraction, verify the BIU firmware status and safety protocols for the specific machine process before performing removal to prevent unintended state changes.\u003c\/p\u003e\n\u003cp\u003eQ: Is there an internal protection mechanism for inductive loads?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each output channel is equipped with an integrated RC snubber circuit designed to suppress voltage transients during the switching of inductive loads.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be used for high-frequency pulse width modulation (PWM)?\u003c\/p\u003e\n\u003cp\u003eA: No, this is a relay-based output module limited to 20 cycles\/min for inductive loads. It is not suitable for high-speed switching applications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is securely seated into the Field Control I\/O base. Verify that the mechanical locking mechanism is engaged to maintain electrical continuity with the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e To minimize electromagnetic interference (EMI), ensure the I\/O base is connected to a low-impedance common ground. Use shielded cabling for field wiring where induced noise from external power sources is present.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Limits:\u003c\/strong\u003e Ensure field wiring corresponds to the rated current limits of 2 A per point. Utilize appropriate terminal lugs to prevent mechanical stress on the relay terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Given the operational range of -40 deg C to +70 deg C, ensure adequate ventilation within the control cabinet to prevent localized hot spots near high-density I\/O clusters.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52628667793720,"sku":"IC670MDL930","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC670MDL9302.jpg?v=1783584424","url":"https:\/\/www.automodulexpert.com\/products\/ic670mdl930-field-control-i-o-module-ge-fanuc","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}