{"product_id":"ic694mdl754-cd-ge-digital-output-module","title":"IC694MDL754-CD GE Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC694MDL754-CD is a high-density digital output module for the GE PACSystems RX3i platform. This 100% brand new, original module provides 32 sourcing (positive logic) output points in a single-slot design. It is intended for controlling 12\/24 VDC field devices such as solenoids, relays, motor starters, and indicator lamps. The module incorporates Electronic Short Circuit Protection (ESCP) to enhance reliability and protect field wiring and internal circuitry in demanding industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eIC694MDL754-CD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e32 (4 groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003ePositive logic (sourcing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10.2 – 28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point (2.0 A max per common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eElectronic Short Circuit Protection (ESCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e2 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 × 14.0 × 14.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003e100% Brand New Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated ESCP Protection\u003c\/strong\u003e\u003cbr\u003eReal-time electronic current monitoring detects overloads or short circuits and disables only the affected output point, preventing module-wide failure and eliminating the need for replaceable fuses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Sourcing Output Design\u003c\/strong\u003e\u003cbr\u003e32 sourcing outputs in a single slot significantly reduce rack space requirements while aligning with standard industrial DC control wiring practices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSegmented Group Architecture\u003c\/strong\u003e\u003cbr\u003eOutputs are divided into four independent 8-point groups, limiting fault propagation and maintaining system stability even when one field segment experiences a wiring issue.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostic Capability\u003c\/strong\u003e\u003cbr\u003eFault status is reported directly to the RX3i CPU, enabling precise identification of failed output channels through engineering software for faster maintenance and reduced downtime.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens when ESCP activates?\u003c\/strong\u003e\u003cbr\u003eThe affected output channel is automatically shut down to protect the module. After clearing the external fault, the channel can be reset via PLC logic or system restart procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of wiring connection is required?\u003c\/strong\u003e\u003cbr\u003eA 40-pin high-density Fujitsu-style connector is used. Field wiring is typically connected via a pre-wired cable or terminal block assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module switch AC loads?\u003c\/strong\u003e\u003cbr\u003eNo. It is strictly designed for 12–28.8 VDC operation. AC switching will damage the output circuitry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the “CD” revision backward compatible?\u003c\/strong\u003e\u003cbr\u003eYes. The CD revision is a hardware update and remains fully compatible with existing RX3i backplanes as a direct replacement for earlier IC694MDL754 versions.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52213350629688,"sku":"IC694MDL754-CD","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC694MDL754-CD1.jpg?v=1776305001","url":"https:\/\/www.automodulexpert.com\/products\/ic694mdl754-cd-ge-digital-output-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}