{"product_id":"ic695cmm004-ge-fanuc-communication-module","title":"IC695CMM004 GE Fanuc Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695CMM004\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile communication bridge for the PACSystems RX3i platform, providing four independent serial ports for interfacing with legacy and third-party devices like barcode readers, HMIs, motor drives, and printers. Supporting multiple industrial protocols, it offers flexible wiring options for both short-range and long-range serial data transmission. Supplied in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal condition, it ensures high-performance data exchange in demanding environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Independent Serial Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU Master\/Slave, SNP\/SNPX, Serial I\/O (ASCII)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-422, RS-485 (software selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 bps to 115.2 Kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCI (Universal Backplane only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e470 mA @ 3.3 VDC; 10 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.2 cm x 12.2 cm x 6.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Protocol Versatility\u003c\/strong\u003e: Supports Modbus, SNP, and CCM protocols across different ports for seamless communication with diverse field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware-Configurable Ports\u003c\/strong\u003e: Configure physical interface (RS-232\/422\/485) and communication settings via PAC Machine Edition (PME) software—no manual jumper settings required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Connectivity\u003c\/strong\u003e: Four ports in a single-slot module reduce space usage and system cost for serial-heavy applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Electrical Isolation\u003c\/strong\u003e: Provides isolation between serial ports and the backplane to protect against ground loops and electrical surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics\u003c\/strong\u003e: Front-panel LEDs show real-time TX\/RX activity and module health, simplifying fault isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich RX3i slots support the IC695CMM004?\u003c\/strong\u003e\u003cbr\u003eIt requires a PCI-capable slot within the RX3i Universal Backplane. It does not work in older expansion or serial-only racks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use all four ports for Modbus RTU at the same time?\u003c\/strong\u003e\u003cbr\u003eYes, each port can be independently configured as a Modbus Master or Slave, supporting multi-drop network architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require an external power supply?\u003c\/strong\u003e\u003cbr\u003eNo, it draws all necessary power from the RX3i backplane bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I wire the RS-485 connections?\u003c\/strong\u003e\u003cbr\u003eUse compatible terminal blocks or custom cables for 2-wire or 4-wire RS-485 configurations commonly used in industrial networks.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52186243662136,"sku":"IC695CMM004","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC695CMM004_a729fd59-8bb8-42cd-bcf3-657ef1fd077e.jpg?v=1776130633","url":"https:\/\/www.automodulexpert.com\/products\/ic695cmm004-ge-fanuc-communication-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}