{"product_id":"ic695pbm300-profibus-master-module-ge-fanuc","title":"IC695PBM300 PROFIBUS Master Module GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695PBM300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS DP Master\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE PACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It enables seamless communication between the RX3i CPU and decentralized field devices such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVFDs\u003c\/strong\u003e, and other\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS-compliant\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edevices. Using the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed PCI bus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof the RX3i backplane, the module ensures rapid data throughput and low latency, making it a crucial component for integrating multi-vendor fieldbus networks into a centralized GE control system. Guaranteed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor optimal network infrastructure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP-V0, DP-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12 Mbps\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(auto-detecting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNode Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e125 DP slaves\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eRX3i Universal Backplane\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(PCI Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e3,584 bytes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einput,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3,584 bytes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e23.0 cm x 15.3 cm x 3.2 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.72 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Network Integration\u003c\/strong\u003e: Supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDP-V0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDP-V1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocols, allowing basic cyclic data exchange and advanced diagnostics for smart field instruments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Configuration\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProficy Machine Edition (PME)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware enables easy import of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGSD files\u003c\/strong\u003e, streamlining network configuration and reducing setup time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Diagnostics\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9-pin D-sub connector\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor network analysis and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time LED indicators\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto monitor module health and network status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Data Transfer\u003c\/strong\u003e: The use of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePCI bus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures high-bandwidth performance, preventing bottlenecks even with large node counts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Does this module support PROFIBUS DP-V1 features?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695PBM300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efully supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDP-V1 acyclic messaging\u003c\/strong\u003e, allowing for reading and writing complex parameters and diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How many PROFIBUS Master modules can I install in one RX3i rack?\u003c\/strong\u003e\u003cbr\u003eYou can install multiple\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695PBM300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules, depending on available\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePCI slots\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Is this module compatible with the RX3i redundant CPU system?\u003c\/strong\u003e\u003cbr\u003eYes, it is compatible, but ensure to verify bumpless transfer requirements for field devices in redundant configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What type of cable is required for connection?\u003c\/strong\u003e\u003cbr\u003eThe module requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS-certified shielded twisted-pair cables\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9-pin D-sub\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnector and integrated terminating resistor for signal integrity at high baud rates.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52136996962616,"sku":"IC695PBM300","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC695PBM3001.jpg?v=1775702927","url":"https:\/\/www.automodulexpert.com\/products\/ic695pbm300-profibus-master-module-ge-fanuc","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}