{"product_id":"igp10-a22e1f-m2t-pressure-transmitter-foxboro","title":"IGP10-A22E1F-M2T Pressure Transmitter Foxboro","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIGP10-A22E1F-M2T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-accuracy intelligent gauge pressure transmitter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFoxboro I\/A Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eportfolio. Although sometimes generically referred to as a “module,” it is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecision field instrument\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to measure liquid, gas, or vapor pressure and convert it into a stable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA analog signal with HART digital communication\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis configuration features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e316L stainless steel diaphragm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esilicone fill fluid\u003c\/strong\u003e, delivering long-term stability and repeatable accuracy in demanding process environments. Advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esilicon strain-gauge sensing technology\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides excellent ambient temperature compensation, while the epoxy-coated aluminum housing with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP66 \/ NEMA 4X\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotection safeguards the electronics against moisture and corrosive atmospheres. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM2 LCD indicator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT option\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenhance local visibility, configuration, and installation flexibility for field maintenance personnel.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Model Code\u003c\/td\u003e\n\u003ctd\u003eIGP10-A22E1F-M2T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd\u003eIntelligent Gauge Pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA with HART protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel diaphragm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFill Fluid\u003c\/td\u003e\n\u003ctd\u003eSilicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection\u003c\/td\u003e\n\u003ctd\u003e1\/2 in NPT (external thread)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003eHigh-range (up to approx. 21 MPa \/ 3000 psi, model-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05% of calibrated span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e11.5–42 V DC (loop-powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Interface\u003c\/td\u003e\n\u003ctd\u003eM2 digital LCD indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X \/ IP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"selectTdClass\"\u003eHazardous Area Approvals\u003c\/td\u003e\n\u003ctd class=\"selectTdClass\"\u003eExplosion-proof \/ Flameproof (model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIGP10-A22E1F-M2T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eheavy industrial and utility applications\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePump discharge and suction pressure monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage tank vapor space pressure measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam header and boiler auxiliary systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and hydrocarbon processing units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts combination of high accuracy, environmental robustness, and hazardous-area certification makes it suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecritical pressure measurement points\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the “T” suffix indicate in the model code?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“T” option\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically denotes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especific mounting or tagging configuration\u003c\/strong\u003e, often associated with a stainless steel mounting bracket for pipe or surface installation. Exact details should be confirmed against the Foxboro model code datasheet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can zero and span be adjusted without a HART communicator?\u003c\/strong\u003e\u003cbr\u003eA: Yes. When equipped with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM2 LCD indicator\u003c\/strong\u003e, basic zero and span adjustments can be performed using the local pushbuttons. A HART communicator is still recommended for full configuration and advanced diagnostics.\u003c\/p\u003e","brand":"FOXBORO","offers":[{"title":"Default Title","offer_id":51633988665656,"sku":"IGP10-A22E1F-M2T","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IGP10-A22E1F-M2T.jpg?v=1768874760","url":"https:\/\/www.automodulexpert.com\/products\/igp10-a22e1f-m2t-pressure-transmitter-foxboro","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}