{"product_id":"immfp03-abb-symphony-infi-90-multi-function-processor-module","title":"IMMFP03 ABB Symphony Infi 90 Multi-Function Processor Module","description":"\u003ch2\u003eABB IMMFP03 Symphony Infi 90 Multi-Function Processor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB IMMFP03\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIMMFP03\u003c\/strong\u003e Multi-Function Processor Module, operates as a dedicated hardware component for direct physical\/electrical execution of real-time process control, data acquisition, and sequential execution within ABB Bailey Symphony Infi 90 DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix \/ Variant\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eMemory Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProcessor Speed\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIMMFP03\u003c\/td\u003e\n\u003ctd\u003eStandard (IMMFP03)\u003c\/td\u003e\n\u003ctd\u003e2 MB SRAM, 512 KB NVRAM, 512 KB ROM\u003c\/td\u003e\n\u003ctd\u003e32-bit, 32 MHz\u003c\/td\u003e\n\u003ctd\u003eCore process control execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIMMFP03\u003c\/td\u003e\n\u003ctd\u003eVariant B (IMMFP03B)\u003c\/td\u003e\n\u003ctd\u003e8 MB SRAM, 2 MB NVRAM, 512 KB ROM\u003c\/td\u003e\n\u003ctd\u003e32-bit, 32 MHz\u003c\/td\u003e\n\u003ctd\u003eHigh-density data \u0026amp; batch processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIMMFP03 (IMMFP03B \/ PIMMFP03 \/ IMMFP03R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB \/ Bailey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg (1.1 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 cm x 5.1 cm x 33.0 cm (7.0 in x 2.0 in x 13.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W typical (+5 VDC, 2 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicroprocessor\u003c\/td\u003e\n\u003ctd\u003e32-bit, 32 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-Board Memory\u003c\/td\u003e\n\u003ctd\u003e2 MB SRAM, 512 KB NVRAM, 512 KB ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eSupports up to 64 I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Architecture\u003c\/td\u003e\n\u003ctd\u003eControlway bus, I\/O Expander Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eHot-standby redundancy with bumpless transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537109060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB IMMFP03\u003c\/strong\u003e interfaces directly with the proprietary Controlway backplane structure to optimize deterministic data throughput across system nodes. Integrated firmware flash compatibility permits continuous verification of internal task execution cycles while maintaining high-speed serial arbitration over the I\/O Expander Bus. This internal control loop execution maintains deterministic latencies during hot-standby redundancy transfers, preventing signal interruption across connected channel modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is primary operational power delivered to the IMMFP03 processor module?\u003c\/p\u003e\n\u003cp\u003eA: Power is drawn directly from the backplane rack power bus at a nominal rating of +5 VDC at 2 A, resulting in a continuous power dissipation of approximately 10 W.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support hot-standby redundant configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, dual IMMFP03 units can be installed in a paired module rack setup to provide hot-standby hardware redundancy with automatic bumpless transfer upon detection of a primary controller fault.\u003c\/p\u003e\n\u003cp\u003eQ: What expansion options exist for serial device communication on this module?\u003c\/p\u003e\n\u003cp\u003eA: The IMMFP03 utilizes an optional IMMPI01 module interface to establish dedicated serial port connectivity for external system communication.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the rack slot keying matches the physical configuration of the IMMFP03 prior to inserting the card into the backplane connector.\u003c\/li\u003e\n\u003cli\u003eDe-energize system backplane power or verify redundant bus status before performing module insertion or removal procedures.\u003c\/li\u003e\n\u003cli\u003eFasten top and bottom faceplate captive screws securely to the rack enclosure frame to establish a low-impedance ground connection.\u003c\/li\u003e\n\u003cli\u003eMaintain shield wire grounding continuity for all high-speed serial lines connected via external communication modules to prevent noise pickup.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52960210485560,"sku":"IMMFP03","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/586..jpg?v=1789452522","url":"https:\/\/www.automodulexpert.com\/products\/immfp03-abb-symphony-infi-90-multi-function-processor-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}