{"product_id":"is200egdmh1aff-general-electric-field-ground-detector-new-original-stock","title":"IS200EGDMH1AFF General Electric Field Ground Detector | New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS200EGDMH1AFF\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200EGDMH1\u003c\/strong\u003e Exciter Field Ground Detector Module, operates as a dedicated hardware component for continuous insulation monitoring within EX2100 excitation control systems. This module provides direct electrical sensing of the generator field winding relative to ground potential.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EGDMH1AFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.54 kg (1 lbs 3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22.86 cm x 15.24 cm x 3.81 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eExciter Power Backplane Rack (EPBP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eExciter Ground Detection and Fail-Safe Execution\u003c\/h3\u003e\n\u003cp\u003eThe module is engineered to detect high-impedance faults in the generator field circuit. It employs a bridge-circuit topology to continuously monitor the voltage potential of both the positive and negative field buses. If the measured leakage current exceeds the programmed threshold, the module initiates a hardware interrupt to the excitation regulator, signaling the control system to execute a controlled shutdown or annunciation. This process ensures fail-safe state execution by preventing prolonged operation under compromised insulation conditions, which would otherwise lead to catastrophic rotor winding damage.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IS200EGDMH1AFF be replaced while the exciter is online?\u003c\/p\u003e\n\u003cp\u003eA: The module can be replaced during operation provided the EX2100 system is placed in \"Test\" or \"Off\" mode for the ground detection function via the operator interface to avoid nuisance trips during the module insertion\/removal transition.\u003c\/p\u003e\n\u003cp\u003eQ: What does the \"AFF\" suffix indicate regarding hardware compatibility?\u003c\/p\u003e\n\u003cp\u003eA: The \"AFF\" suffix denotes the specific hardware revision level. When replacing this module, it is required to verify that the replacement unit maintains firmware flash compatibility with the existing EX2100 control software, as older revision levels may not support the sensitivity parameters required by newer control constants.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is firmly seated into the designated slots on the Exciter Power Backplane (EPBP). The module relies on the backplane for both communication and low-voltage power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify that the chassis ground connection on the EPBP is clean and secure. Poor grounding impedance will cause erroneous ground fault readings due to induced common-mode noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Wiring:\u003c\/strong\u003e When connecting field monitoring leads, ensure wires are routed through the designated EMI-shielded conduits. Field leads must be isolated from high-voltage AC circuits to prevent insulation breakdown of the sensing input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e After physical installation, perform a verification of the ground detection sensitivity via the GEI-100467 manual procedures to confirm the module correctly reports the reference voltage levels to the regulator.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52493449593144,"sku":"IS200EGDMH1AFF","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200EGDMH1AFF1.jpg?v=1781165690","url":"https:\/\/www.automodulexpert.com\/products\/is200egdmh1aff-general-electric-field-ground-detector-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}