{"product_id":"is200epctg1a-ge-excitation-terminal-board-new-original-stock","title":"IS200EPCTG1A GE Excitation Terminal Board | New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200EPCTG1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200EPCTG1\u003c\/strong\u003e Terminal Board, operates as a dedicated hardware component for potential transformer (PT) and current transformer (CT) signal conditioning within EX2100 Excitation Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EPCTG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e23.8 cm x 8.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e28 V DC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator PT Inputs\u003c\/td\u003e\n\u003ctd\u003eTwo 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator CT Inputs\u003c\/td\u003e\n\u003ctd\u003eTwo (1 A or 5 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Length\u003c\/td\u003e\n\u003ctd\u003e1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Compatibility\u003c\/td\u003e\n\u003ctd\u003eUp to #10 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IS200EPCTG1A functions as the primary interface for generator voltage and current monitoring, utilizing integrated isolation transformers to perform signal conditioning before data is passed to the excitation control processor. The board maintains deterministic signal throughput to ensure that the excitation regulator receives synchronized data for voltage and current feedback loops. Firmware flash compatibility is managed through the host EX2100 controller architecture; users must ensure the control software revision is verified for the \"A\" board variation to support the integrated signal processing logic. The backplane interface is optimized for high-speed data acquisition to maintain stability during transient grid conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IS200EPCTG1A handle both 1 A and 5 A CT inputs? A: Yes, the board is configured to accept either 1 A or 5 A current transformer inputs. Ensure the internal board jumpers or software configuration settings match the specific CT ratio installed in the field to prevent measurement scaling errors.\u003c\/p\u003e\n\u003cp\u003eQ: Are the PT\/CT inputs galvanically isolated on this board? A: The board utilizes integrated isolation transformers for both PT and CT inputs, providing necessary galvanic isolation between high-voltage generator circuits and the low-voltage excitation control backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the control cabinet is de-energized and verified for zero energy before beginning installation. Use standard PPE when working with PT\/CT secondary circuits.\u003c\/li\u003e\n\u003cli\u003eWhen terminating conductors up to #10 AWG, ensure that the wire strands are fully captured by the terminal block and tightened to the manufacturer's specified torque to prevent overheating or signal intermittent contact.\u003c\/li\u003e\n\u003cli\u003eMaintain strict separation between the secondary CT\/PT circuits and low-voltage control signal wiring to prevent induced noise on the analog inputs.\u003c\/li\u003e\n\u003cli\u003eGround the terminal board mounting chassis to the cabinet common ground bus to ensure the effectiveness of the onboard electromagnetic shielding.\u003c\/li\u003e\n\u003cli\u003eVerify that the total loop resistance for the 1000 feet maximum cable length does not exceed the impedance threshold for the connected PT\/CT sensors, as excessive length can result in signal attenuation and phase shift.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52487610401080,"sku":"IS200EPCTG1A","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200EPCTG1A.jpg?v=1781078008","url":"https:\/\/www.automodulexpert.com\/products\/is200epctg1a-ge-excitation-terminal-board-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}