{"product_id":"is200epsmg2a-ge-power-supply-module-new-original-stock","title":"IS200EPSMG2A GE Power Supply Module | New \u0026 Original Stock","description":"\u003cp\u003eConfigured for excitation control in EX2100 network platforms, the \u003cstrong\u003eGE IS200EPSMG2A\u003c\/strong\u003e (\u003cstrong\u003eIS200EPSM\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200\u003c\/strong\u003e: Designates the series and domestic original manufacture origin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPSM\u003c\/strong\u003e: Functional identifier for the Exciter Power Supply Module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG2\u003c\/strong\u003e: Denotes the application of PCB protective conformal coating and integration within the Group 2 EX2100 Series architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Specifies the functional revision level of the assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EPSMG2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard EX2100 rack format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoad dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Wetting Supply\u003c\/td\u003e\n\u003ctd\u003e70 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 15 VDC, and 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC\/DCS Firmware and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200EPSMG2A\u003c\/strong\u003e interacts with the EX2100 backplane to distribute regulated power to peripheral control logic. Integration is governed by backplane bus communication velocity parameters inherent to the EX2100 platform. Firmware flash compatibility is managed through the main exciter controller, which verifies the module revision (G2) during the power-on self-test (POST) sequence. The unit maintains stable DC output rails (5 VDC, 15 VDC, and 24 VDC) to support I\/O density scaling requirements within the excitation cabinet.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200EPSMG2A support hot-swapping during excitation operation? A: Hot-swapping is not recommended for this module. The excitation system should be placed in a non-run state and the cabinet power isolated before physically removing or inserting the board to prevent transient surges on the backplane.\u003c\/p\u003e\n\u003cp\u003eQ: How is the 70 VDC contact wetting supply utilized? A: The 70 VDC rail is dedicated to maintaining signal integrity across input contact loops, preventing oxide buildup on relay contacts connected to the exciter control system.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the Exciter Control System is in a hardware-safe state with all primary AC and DC power sources disconnected.\u003c\/li\u003e\n\u003cli\u003eEnsure the PCB is aligned precisely with the EX2100 guide rails to prevent damage to the backplane edge connector pins.\u003c\/li\u003e\n\u003cli\u003eApply uniform pressure to the extraction levers until the module is fully seated and the locking mechanisms engage.\u003c\/li\u003e\n\u003cli\u003eVerify the integrity of the conformal coating on the board edges; ensure no physical damage occurred during handling.\u003c\/li\u003e\n\u003cli\u003eConnect external wiring to the designated screw terminals; ensure wire stripping length complies with site standards for terminal block engagement.\u003c\/li\u003e\n\u003cli\u003eCheck for proper chassis grounding before restoring power to the exciter cabinet.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52479410372920,"sku":"IS200EPSMG2A","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200EPSMG2AED_1.jpg?v=1731922270","url":"https:\/\/www.automodulexpert.com\/products\/is200epsmg2a-ge-power-supply-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}