{"product_id":"is200erioh1acb-general-electric-exciter-board-new-original-stock","title":"IS200ERIOH1ACB General Electric Exciter Board | New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS200ERIOH1ACB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200ERIOH1ACB\u003c\/strong\u003e Exciter Regulator I\/O Board, operates as a dedicated hardware component for high-speed signal processing and excitation logic management within Mark VI turbine control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ERIOH1ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.2 cm x 25.4 cm x 3.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eExcitation Regulator I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eMark VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200ERIOH1ACB facilitates deterministic communication between the excitation regulator and the control processor. By integrating directly into the Mark VI backplane, the board ensures low-latency execution of excitation control commands and monitoring of generator field feedback. The module supports high-speed signal conditioning, converting raw field data into precise digital inputs for the control logic. Firmware flash compatibility is built into the board's architecture, allowing for field updates to excitation algorithms and diagnostic tracking without the need for hardware replacement, thus maintaining consistent network timing and control loop stability.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200ERIOH1ACB support hot-swapping during excitation system operation?\u003c\/p\u003e\n\u003cp\u003eA: No, this board is not designed for hot-swapping. The excitation regulator must be disabled and the rack power isolated before the board is removed or installed to prevent electrical damage to the I\/O bus or connected field devices.\u003c\/p\u003e\n\u003cp\u003eQ: How can I verify the board's health status via the excitation control interface?\u003c\/p\u003e\n\u003cp\u003eA: The board status is reflected in the diagnostic logs of the Mark VI controller. A functional board will report healthy communication flags; failure to sync or internal logic errors will trigger specific diagnostic alarm codes on the operator interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the excitation power supply is fully isolated and locked out according to standard safety procedures.\u003c\/li\u003e\n\u003cli\u003eAlign the board with the chassis rails to ensure proper seating into the backplane connector; avoid forcing the board, which could cause pin misalignment.\u003c\/li\u003e\n\u003cli\u003eOnce seated, tighten the captive screws on the faceplate to ensure electrical continuity for the grounding system and structural stability.\u003c\/li\u003e\n\u003cli\u003eVerify that all field-side I\/O connections are properly landed on the terminal block and that cable shields are grounded at the designated common point to suppress EMI.\u003c\/li\u003e\n\u003cli\u003eInspect the interface cable connections for secure latching before re-energizing the excitation rack.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52483339157816,"sku":"IS200ERIOH1ACB","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200VRTDH1D2.jpg?v=1780990994","url":"https:\/\/www.automodulexpert.com\/products\/is200erioh1acb-general-electric-exciter-board-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}