{"product_id":"is200examg1baa-ge-exam-exciter-attenuation-module","title":"IS200EXAMG1BAA GE EXAM Exciter Attenuation Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200EXAMG1BAA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eEXAM\u003c\/strong\u003e Exciter Attenuation Module, operates as a dedicated hardware component for signal conditioning and noise attenuation within EX2100 control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EXAMG1BAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 80 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC (+\/- 10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet, Serial Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003e16 Analog\/Digital Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Control System Signal Integrity Architecture\u003c\/h3\u003e\n\u003cp\u003eThe EXAM module functions as a high-precision interface for mitigating electromagnetic interference (EMI) within the excitation loop. Utilizing high-speed backplane bus communication velocity, the board synchronizes attenuated analog feedback signals with the main excitation controller. Firmware flash compatibility enables real-time adjustments to attenuation curves and filtering logic, allowing the system to adapt to varying electrical noise environments. The module supports I\/O density scaling, providing 16 configurable channels that can be mapped for either analog sensing or digital status monitoring, ensuring optimal signal fidelity for sensitive excitation control loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary purpose of the attenuation logic on this module?\u003c\/p\u003e\n\u003cp\u003eA: The attenuation circuitry is designed to suppress high-frequency noise and voltage transients that can degrade the quality of sensitive feedback signals in the excitation path, ensuring that the controller receives clean, accurate data.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module capable of being mounted in different industrial configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the IS200EXAMG1BAA is designed for both DIN-rail and panel mounting, providing flexibility for installation in standard excitation cabinets or remote junction boxes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the module to a grounded DIN rail or panel using the integrated mounting hardware. Ensure sufficient clearance for airflow, as the module requires ambient dissipation for operation at high temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: For optimal noise attenuation, connect the chassis ground terminal to a low-impedance earth bus. Proper grounding is critical for the efficacy of the internal filtering circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Maintain a strict separation between signal cabling and high-power conductors. Use shielded twisted-pair cables for all analog inputs, terminating the shield drain wire at a single point to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Port Configuration\u003c\/strong\u003e: Before integrating into the network, ensure the serial interface and Ethernet parameters are synchronized with the host controller. Verify the status of the diagnostic LEDs upon power-up to confirm successful communication handshake.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52546368274744,"sku":"IS200EXAMG1BAA","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200EXAMG1BAA1.jpg?v=1782116013","url":"https:\/\/www.automodulexpert.com\/products\/is200examg1baa-ge-exam-exciter-attenuation-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}