Configured for high-precision temperature sensing in Mark VI control system networks, the GE IS200SRTDH2ACB (IS200SRTDH2 RTD Input Terminal Board) provides direct physical signal termination for resistance temperature detector inputs. This hardware component facilitates the connection of field-side temperature sensors to the I/O pack, converting raw resistive measurements into digital data streams for processor execution.
Suffix Breakdown & Model Matrix
The IS200SRTDH2ACB nomenclature identifies the specific hardware iteration of the Mark VI series. The "IS200" prefix designates the GE Mark VI component category, while "SRTD" identifies the terminal board as a specialized RTD input variant. The suffix "ACB" denotes the version and board assembly revision, representing the physical layout and trace topology specific to this model.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IS200SRTDH2ACB |
| Brand | GE |
| Origin | United States |
| Weight | 0.6 KG |
| Dimensions | 16.7 cm x 14.8 cm x 5.5 cm |
| Operating Temp | -40 deg C to +70 deg C (Standard Industrial Range) |
| Power Consumption | Backplane dependent |
| I/O Type | RTD Input |
| PCB Construction | Multi-layer printed circuit board |
Profinet / EtherNet/IP Deterministic Networks
The board ensures deterministic connectivity within the GE Mark VI control fabric by maintaining low-impedance paths between the terminal interface and the I/O pack backplane. Signal integrity is maintained through optimized PCB trace routing, which minimizes cross-talk between high-density RTD channels. Firmware compatibility must be verified with the host controller to ensure that the sampling frequency and cold junction compensation logic (if applicable to specific RTD configurations) are properly mapped within the processor's scan cycle.
Frequently Asked Questions
Q: Does this board support 3-wire and 4-wire RTD configurations?
A: Yes, the board is designed to interface with standard RTD wiring configurations. Users must verify the specific jumper or software settings within the control application to match the physical wiring setup to ensure bridge completion and resistance measurement accuracy.
Q: Is this board susceptible to signal noise from nearby high-voltage lines?
A: As a sensitive analog interface, the board requires strict adherence to signal segregation. Field wiring must be shielded and grounded at a single point to prevent ground loops and common-mode noise, which could otherwise introduce fluctuations in the measured resistance value.
Field Installation Guidelines
- Ensure the control cabinet power is completely disconnected before seating the terminal board on its mounting standoff.
- Align the board to ensure correct connector mating with the backplane; verify that no pins are deformed during insertion.
- Maintain a minimum distance of 15 cm from high-frequency switching or power supply cabling to avoid induced noise on the low-level RTD signal lines.
- Secure all terminal screws to the specified torque rating to prevent intermittent high-resistance connections caused by thermal expansion or vibration.
- Perform a channel verification test by simulating a known resistance value at the field terminal block to calibrate the signal path before connecting live process sensors.
| Quick Quotes | Receive price & availability FAST from our dedicated customer service team. |
|---|---|
| Delivery | Expedited, Freight, And International Shipping Available. |
| Condition | 100% New with Original Package |
| Payment | We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL. |
| Shipping Port | ShangHai, Xiamen |
| Warranty | 12 Months |
| Q: Is Our Pricing Competitive? |
| A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends. |
| Q: What Is the Warranty Period? |
| A: All our new and original products come with a standard one-year warranty. |
| Q: What Payment Methods Do We Accept? |
| A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them. |
| Q: What Shipping Methods Do We Use? |
| A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders. |
| Q: What Is Our Delivery Time? |
| A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule. |
| Q: How Do We Package the Goods? |
| A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes. |
| Q: How Can Customers Contact Us and Request a Quote? |
| A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote. |