{"product_id":"is200staih2aaa-ge-analog-input-terminal-board","title":"IS200STAIH2AAA GE Analog Input Terminal Board","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200STAIH2AAA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200STAIH2\u003c\/strong\u003e Analog Input Terminal Board, operates as a dedicated hardware component for signal termination and interface conditioning within Mark VI control system networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200STAIH2AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e33 cm x 17.8 cm x 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e12 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA \/ 1-5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Gauge\u003c\/td\u003e\n\u003ctd\u003e12 to 24 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorque Rating\u003c\/td\u003e\n\u003ctd\u003e0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eControl System Connectivity and Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe IS200STAIH2AAA serves as the physical interface between field-mounted instrumentation and the Mark VI I\/O pack. It facilitates backplane bus communication by providing stable signal paths and noise-filtering circuitry. The board ensures deterministic data transmission by maintaining signal integrity at the terminal block level, preventing latency often associated with unshielded analog circuits. Integration requires verification of firmware flash compatibility within the associated I\/O pack to ensure correct mapping of input channels to the controller's control logic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this terminal board support both current and voltage inputs simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the STAI board supports configurable inputs for 4-20 mA or 1-5 VDC signals. Ensure jumpers on the terminal board are set according to the application-specific loop requirements before energizing.\u003c\/p\u003e\n\u003cp\u003eQ: Is this board field-repairable if a terminal block is damaged?\u003c\/p\u003e\n\u003cp\u003eA: The board utilizes removable screw-type terminals. If a specific terminal block sustains mechanical damage, the individual block can be replaced without requiring the removal of the entire board from the cabinet, provided the system is isolated.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the board is mounted in a standard Mark VI cabinet using the designated standoffs to maintain proper electrical clearance and backplane alignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate field signal wires to the removable screw blocks. Ensure the wires are stripped to the appropriate length to prevent exposed copper, while maintaining the 0.5 Nm torque specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Connect signal cable shields to the cabinet ground bus provided on the terminal board mounting plate. Do not terminate shields at the signal input terminals to avoid ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Use a calibrated multimeter to verify loop voltage or current at the terminals before commissioning the associated I\/O pack to prevent input channel overload.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52495953592632,"sku":"IS200STAIH2AAA","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200STAOH2AAA.jpg?v=1765176492","url":"https:\/\/www.automodulexpert.com\/products\/is200staih2aaa-ge-analog-input-terminal-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}