{"product_id":"is200tbcih1bbc-is200tbcih1b-general-electric-terminal-board-new-original-stock","title":"IS200TBCIH1BBC IS200TBCIH1B General Electric Terminal Board | New \u0026 Original Stock","description":"\u003cp\u003eConfigured for analog signal termination and field wiring interfacing in Mark VI control systems, the \u003cstrong\u003eGeneral Electric IS200TBCIH1BBC\u003c\/strong\u003e (\u003cstrong\u003eIS200TBCIH1B\u003c\/strong\u003e Terminal Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200TBCIH1B\u003c\/strong\u003e: Base terminal board identifier for analog I\/O signal routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIS200TBCIH1BBC\u003c\/strong\u003e: Specific assembly iteration featuring modified terminal interface layout and improved connector keying for I\/O signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TBCIH1BBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e33 cm x 10.2 cm x 4.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Loop powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-rail \/ Panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Density\u003c\/td\u003e\n\u003ctd\u003e24-channel analog termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200TBCIH1BBC functions as a passive interface board, facilitating the transition from field-side wiring to the controller I\/O pack. Signal integrity is maintained via high-density terminal blocks that minimize impedance mismatch, ensuring that analog signals (e.g., 4-20 mA, 1-5 VDC) are transmitted to the I\/O pack with minimal attenuation. The board supports consistent signal paths required for turbine regulation, ensuring that the backplane-connected controller receives precise voltage references across the deterministic network architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this terminal board require external power to operate?\u003c\/p\u003e\n\u003cp\u003eA: No. The IS200TBCIH1BBC is a passive termination component. Power for the connected I\/O pack and signal loops is supplied directly through the controller backplane or the associated I\/O processor.\u003c\/p\u003e\n\u003cp\u003eQ: Is the terminal board pin-compatible with older IS200TBCI versions?\u003c\/p\u003e\n\u003cp\u003eA: Generally, yes. However, verify the revision suffix (e.g., H1B versus H1BBC) against the existing control cabinet wiring diagram, as terminal positioning and physical keying may vary between specific sub-revisions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure all field wiring is de-energized before connecting wires to the terminal blocks.\u003c\/li\u003e\n\u003cli\u003eSecure the terminal board to the mounting plate using the provided stand-offs to ensure adequate chassis grounding.\u003c\/li\u003e\n\u003cli\u003eStrip wire insulation to the length specified by the terminal block gauge to prevent exposed copper.\u003c\/li\u003e\n\u003cli\u003eRoute field cables through the cable management ducts to ensure no mechanical tension is applied to the board connectors.\u003c\/li\u003e\n\u003cli\u003eApply shielding drain wires to the designated ground terminals on the board to facilitate common-mode noise suppression.\u003c\/li\u003e\n\u003cli\u003eVerify continuity from the field termination point to the I\/O pack connector before commissioning the control loop.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52462609629496,"sku":"IS200TBCIH1BBC IS200TBCIH1B","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200TBCIH1BBC_IS200TBCIH1B1.jpg?v=1780472877","url":"https:\/\/www.automodulexpert.com\/products\/is200tbcih1bbc-is200tbcih1b-general-electric-terminal-board-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}