{"product_id":"is200tbcih1bce-ge-tbci-contact-terminal-board","title":"IS200TBCIH1BCE GE TBCI Contact Terminal Board","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200TBCIH1BCE\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTBCI\u003c\/strong\u003e Contact Terminal Board, operates as a dedicated hardware component for signal termination and field-to-controller interfacing within Mark VI control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TBCIH1BCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e330 mm x 102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eContact input signal termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VI Signal Processing Architecture\u003c\/h3\u003e\n\u003cp\u003eThe TBCI board functions as the primary interface for processing digital contact inputs. Utilizing high-speed backplane bus communication velocity, the board facilitates the deterministic transfer of field-state data (open\/closed) to the I\/O processor modules. The board supports I\/O density scaling, allowing for the organized termination of multiple digital input loops within the control cabinet. As a passive termination component, it ensures signal integrity through robust terminal connections, providing a stable path between field-level sensors and the Mark VI input modules without active signal conversion.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200TBCIH1BCE module require external power for operation?\u003c\/p\u003e\n\u003cp\u003eA: No, the TBCI board is a passive termination component. It is designed to pass signals to and from the Mark VI digital input modules, which provide the necessary interrogation voltage to the field contacts.\u003c\/p\u003e\n\u003cp\u003eQ: How should digital input contacts be wired to this board to prevent noise interference?\u003c\/p\u003e\n\u003cp\u003eA: Use shielded, twisted-pair cabling for all digital inputs. Terminate the cable shields at the designated chassis grounding lugs provided on the cabinet mounting plate to ensure effective protection against electromagnetic interference (EMI).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the TBCI board to the control cabinet backplane using the mounting studs. Ensure the mounting surface is unpainted to facilitate a low-impedance ground connection for the board's common plane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Specifications\u003c\/strong\u003e: Use a calibrated screwdriver to tighten terminal screws to the specified torque value. Overtightening can cause damage to the terminal blocks, while undertightening may cause intermittent contact faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Mapping\u003c\/strong\u003e: Cross-reference the specific terminal numbers on the board with the system design documentation to ensure correct I\/O mapping before initiating the commissioning process.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Inspection\u003c\/strong\u003e: Perform a physical inspection of all soldered joints and terminal connectors before applying power. Ensure no stray wire strands are bridging adjacent terminals, which could cause a false input signal or a short circuit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52546400846136,"sku":"IS200TBCIH1BCE","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200TBCIH1BCE.jpg?v=1782116012","url":"https:\/\/www.automodulexpert.com\/products\/is200tbcih1bce-ge-tbci-contact-terminal-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}