{"product_id":"is200tdbsh6abc-ge-analog-i-o-module-new-original-stock","title":"IS200TDBSH6ABC GE Analog I\/O Module | New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200TDBSH6ABC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TDBSH6\u003c\/strong\u003e Analog I\/O Module, operates as a dedicated hardware component for signal conditioning and analog input\/output processing within Mark VIe control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TDBSH6ABC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard terminal board chassis mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 VDC (backplane powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input \/ Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% FSR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (Channel-to-Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200TDBSH6ABC interfaces directly with the Mark VIe I\/O pack architecture, facilitating deterministic data transfer over the internal backplane bus. Communication velocity and integrity are maintained through high-speed sampling cycles, ensuring synchronization between the analog signal conditioning layer and the controller processor. Users must ensure that firmware revisions on the paired I\/O pack remain compatible with the terminal board's hardware revision state to prevent I\/O scan errors or communication time-outs within the Ethernet-based control fabric.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this terminal board be hot-swapped during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: While the Mark VIe I\/O pack is designed for hot-swapping, the terminal board itself acts as a passive wiring interface. Removal during operation will result in an immediate loss of signal loop continuity; ensure the associated control logic is in a safe or bypassed state before mechanical disconnection.\u003c\/p\u003e\n\u003cp\u003eQ: How should the shield grounding be terminated on this board?\u003c\/p\u003e\n\u003cp\u003eA: Shield terminations must be connected to the dedicated grounding points on the terminal board chassis. Ensure that the total cable impedance to ground is kept minimal to prevent electromagnetic interference (EMI) from affecting the 16-bit analog resolution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the control power is isolated and that the backplane is de-energized prior to installation.\u003c\/li\u003e\n\u003cli\u003eEnsure that the module is securely mounted on the DIN-rail or chassis mounting plate to maintain structural integrity and electrical bonding.\u003c\/li\u003e\n\u003cli\u003eCheck that all signal wiring is stripped to the specified length for the terminal blocks to prevent exposed conductors; torque screws to manufacturer-recommended values.\u003c\/li\u003e\n\u003cli\u003eConfirm that the wiring configuration (4-20 mA or voltage mode) matches the software configuration defined in the ToolboxST application to prevent hardware damage or reading inaccuracy.\u003c\/li\u003e\n\u003cli\u003eVerify that the channel-to-bus isolation is intact by performing a loop resistance check before applying power to the analog circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52479429116216,"sku":"IS200TDBSH6ABC","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200TDBSH6ABC.jpg?v=1780905031","url":"https:\/\/www.automodulexpert.com\/products\/is200tdbsh6abc-ge-analog-i-o-module-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}