{"product_id":"is200trpgh1b-ge-termination-relay-card-new-original-stock","title":"IS200TRPGH1B GE Termination Relay Card | New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200TRPGH1B\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TRPGH1B\u003c\/strong\u003e Termination Relay Card, operates as a dedicated hardware component for signal distribution and relay-based switching within Mark VI control system platforms. This module provides the necessary physical interface to facilitate the routing of discrete I\/O signals between field devices and the main control rack.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TRPGH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 cm x 35 cm x 32 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eTerminal Board Signal Routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200TRPGH1B\u003c\/strong\u003e facilitates backplane bus communication velocity by maintaining stable electrical connections between high-density field wiring and the control module interface. It serves as a passive termination point that supports the deterministic nature of Mark VI networks. Firmware flash compatibility is not applicable to this board directly, as it functions as a physical termination layer; however, ensure that the mating I\/O pack firmware is updated to match the specific revision of the installed termination card to maintain accurate I\/O density scaling and signal interpretation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IS200TRPGH1B be used in a redundant I\/O configuration?\u003c\/p\u003e\n\u003cp\u003eA: Yes, this termination board is designed to interface with Mark VI control packs that support redundant configurations, providing the required wiring points for shared signal inputs.\u003c\/p\u003e\n\u003cp\u003eQ: Is field wiring maintenance permitted while the control system is energized?\u003c\/p\u003e\n\u003cp\u003eA: While terminal connections can be accessed, it is strictly recommended to de-energize the specific field loop circuits before performing any wiring modifications to prevent short-circuiting control signal paths.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The card is designed for standard cabinet mounting. Ensure the mounting surface is clean and that the board is secured using the provided standoffs to maintain proper clearance from the cabinet backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use copper conductors only. Ensure wire terminations are torqued to the specifications provided in the Mark VI hardware manual to prevent contact resistance build-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the board common to the cabinet ground bus using a low-impedance braided strap. This is required for maintaining signal integrity and providing surge protection paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Perform a point-to-point continuity check between the field terminal and the I\/O pack connector before commissioning the loop to ensure no wiring faults exist.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52519980532024,"sku":"IS200TRPGH1B","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200TRPGH1B.jpg?v=1781679434","url":"https:\/\/www.automodulexpert.com\/products\/is200trpgh1b-ge-termination-relay-card-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}