{"product_id":"is200tvbah2a-general-electric-vibration-input-terminal-board-new-original-stock","title":"IS200TVBAH2A General Electric Vibration Input Terminal Board | New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS200TVBAH2A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TVBAH2\u003c\/strong\u003e Vibration Input Terminal Board, operates as a dedicated hardware component for signal termination and conditioning within Mark VI turbine control systems. This board facilitates the interface between field-mounted vibration sensors and the VIBI processor module.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TVBAH2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10 x 13.2 x 5.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Input\u003c\/td\u003e\n\u003ctd\u003eProximity probe \/ Seismic sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail \/ Cabinet standoff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IS200TVBAH2A module supports integration within the Mark VI control architecture by providing high-speed signal pass-through to the associated I\/O processor. Firmware flash compatibility is managed via the host processor, ensuring that the terminal board’s passive conditioning circuits align with the active processing logic. The backplane bus communication velocity is optimized to minimize latency in vibration monitoring loops, ensuring that signal integrity is maintained during transmission to the primary control bus. Proximity probes connected to this board require precise configuration to match the scan rates defined by the firmware version of the VIBI module.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this terminal board capable of performing hot-swap operations?\u003c\/p\u003e\n\u003cp\u003eA: The IS200TVBAH2A is a passive terminal board and can be replaced while the system is powered, provided that all field wiring is properly documented and isolated to prevent short circuits during removal.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module require manual calibration for signal input?\u003c\/p\u003e\n\u003cp\u003eA: The board itself does not contain active processing circuitry; signal scaling and calibration are performed at the associated VIBI processor module level. Ensure the wiring terminal blocks are tightened to specified torque settings to maintain low-impedance connections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Terminate cable shields at the designated ground lugs provided on the chassis standoff to mitigate electromagnetic interference (EMI) and common-mode noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Routing:\u003c\/strong\u003e Maintain physical separation between low-voltage vibration signal cables and high-voltage AC\/DC power conductors to prevent inductive crosstalk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngagement:\u003c\/strong\u003e Verify that all Phoenix-style connectors are fully seated into the terminal board headers. Apply anti-corrosion spray to terminal screws if the installation environment is subject to high humidity or caustic airborne contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the cabinet climate control system maintains an ambient operating temperature below 60 deg C to prevent degradation of onboard passive components.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52493044416824,"sku":"IS200TVBAH2A","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200TVBAH2A.jpg?v=1781165690","url":"https:\/\/www.automodulexpert.com\/products\/is200tvbah2a-general-electric-vibration-input-terminal-board-new-original-stock","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}