{"product_id":"is200wemah1awa-ge-exciter-pt-ct-terminal-board","title":"IS200WEMAH1AWA GE Exciter PT\/CT Terminal Board","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200WEMAH1AWA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200WEMAH1\u003c\/strong\u003e Exciter PT\/CT Terminal Board, operates as a dedicated hardware component for voltage and current signal conditioning within industrial power generation and control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200WEMAH1AWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.5 cm x 5.5 cm x 2.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capability\u003c\/td\u003e\n\u003ctd\u003eDigital and Analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network and Communication Integrity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200WEMAH1AWA\u003c\/strong\u003e leverages PROFINET IO deterministic networks to facilitate high-speed data transmission between the exciter monitoring instrumentation and the central control processor. This integration allows for precise acquisition of PT (Potential Transformer) and CT (Current Transformer) signals, which are critical for maintaining synchronization and excitation stability in generator control loops. The board architecture supports I\/O density scaling, enabling the aggregation of multiple analog and digital inputs while maintaining strict communication timing. Firmware flash compatibility ensures that the interface remains aligned with the latest system-level control logic updates without requiring manual hardware adjustments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the PROFINET IO interface be configured for redundant network topologies?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports standard PROFINET IO configurations, allowing for integration into redundant network segments to ensure high availability of critical measurement data.\u003c\/p\u003e\n\u003cp\u003eQ: How should PT\/CT signal inputs be terminated to prevent measurement errors?\u003c\/p\u003e\n\u003cp\u003eA: Signals must be terminated according to the provided wiring schematic to ensure correct polarity. Shielding must be grounded at the designated chassis landing point to mitigate electromagnetic interference, which can otherwise introduce inaccuracies in analog measurement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the control cabinet is de-energized and local lockout\/tagout procedures are observed before installing the board.\u003c\/li\u003e\n\u003cli\u003eMount the terminal board securely within the chassis, ensuring that the compact footprint does not obstruct adjacent cooling airflow.\u003c\/li\u003e\n\u003cli\u003eConnect the PROFINET IO cabling to the communication port, verifying that the cable is shielded and rated for industrial Ethernet environments.\u003c\/li\u003e\n\u003cli\u003eTerminate all PT and CT field signals to the appropriate I\/O terminals, verifying signal integrity with a digital multimeter before powering the 24 Vdc supply.\u003c\/li\u003e\n\u003cli\u003eConfirm successful communication by monitoring the status indicators on the board and verifying the I\/O state via the system configuration workstation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52555190960440,"sku":"IS200WEMAH1AWA","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IS200WEMAH1AWA.jpg?v=1782287374","url":"https:\/\/www.automodulexpert.com\/products\/is200wemah1awa-ge-exciter-pt-ct-terminal-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}