{"product_id":"isolated-analog-input-module-yokogawa-aip423-s1","title":"Isolated Analog Input Module Yokogawa AIP423-S1","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AIP423-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-precision Analog Input Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for use within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM Distributed Control System (DCS)\u003c\/strong\u003e. This module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 isolated channels\u003c\/strong\u003e, providing critical data acquisition capabilities for various sensor types, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThermocouples (TC)\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eResistance Temperature Detectors (RTD)\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einputs. With its versatility and compact design, the AIP423-S1 centralizes multiple field measurements into a single, reliable hardware footprint.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAIP423-S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Isolated Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Input Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermocouple (TC), Resistance Temperature Detector (RTD), DC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm x 30 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-consumption solid-state design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% Brand New Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel-to-Channel Isolation\u003c\/strong\u003e: Each of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis electrically isolated, preventing ground loops and protecting the DCS backplane from high-voltage transients, ensuring accurate data transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Input Versatility\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAIP423-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRTD\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einputs simultaneously, offering a flexible solution that eliminates the need for multiple dedicated modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Integration\u003c\/strong\u003e: At only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30 mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein width, the module fits into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandard I\/O nodes\u003c\/strong\u003e, optimizing space in crowded cabinets while enabling more measurement points per rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Field Deployment\u003c\/strong\u003e: The module features direct insertion into the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O backplane\u003c\/strong\u003e, reducing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommissioning time\u003c\/strong\u003e. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elow-power design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ereduces heat dissipation, improving the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMean Time Between Failures (MTBF)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003ch4\u003eCan I mix different Thermocouple types on a single AIP423-S1 module?\u003c\/h4\u003e\n\u003cp\u003eYes, the module allows independent configuration for each channel. However, ensure that the terminal block wiring is configured for the specific sensor type defined in your system software.\u003c\/p\u003e\n\u003ch4\u003eDoes this module require an external power supply for the isolated channels?\u003c\/h4\u003e\n\u003cp\u003eThe module draws power directly from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCU\/Node\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebackplane. The power requirements for field-side loops depend on whether you're using passive or active sensors.\u003c\/p\u003e\n\u003ch4\u003eIs this a refurbished or used component?\u003c\/h4\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAIP423-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand comes in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efactory-sealed packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoriginal serial numbers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor warranty tracking.\u003c\/p\u003e\n\u003ch4\u003eWhat are the recommended maintenance steps for the AIP423-S1?\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esolid-state design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequires no routine maintenance beyond\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eregular terminal connection inspections\u003c\/strong\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDiagnostic checks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHuman Interface Station (HIS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan help ensure the health of the channels.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":52007389331768,"sku":"AlP423 S1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AlP423_S1.jpg?v=1774837497","url":"https:\/\/www.automodulexpert.com\/products\/isolated-analog-input-module-yokogawa-aip423-s1","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}