{"product_id":"line-protection-board-ge-ds200lppag1a","title":"Line Protection Board GE DS200LPPAG1A","description":"\u003cp\u003eConfigured for power line monitoring and signal isolation in Mark V turbine control architectures, the \u003cstrong\u003eGE DS200LPPAG1A\u003c\/strong\u003e (\u003cstrong\u003eDS200LPPAG1A\u003c\/strong\u003e Line Protection Board) provides direct physical\/electrical execution. This module acts as a protective interface, managing signal transients and potential surges within the line monitoring circuit to maintain system integrity.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200LPPAG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLogic Level DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003e2 terminal blocks (3 terminals each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Bus Integration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDS200LPPAG1A\u003c\/strong\u003e incorporates 7 configurable jumpers that dictate specific pathing and sensitivity levels for line protection tasks. Its integration into the Mark V environment ensures that voltage fluctuations are filtered before reaching critical drive control components. The board serves as a passive protection layer, and its operational parameters are inherently managed by the system's firmware, which monitors the signals terminated at the board's two terminal blocks. There are no user-accessible flashable components on this specific board; it operates based on fixed hardware logic and configuration-specific jumper settings.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary purpose of the 7 jumpers on this board?\u003c\/p\u003e\n\u003cp\u003eA: The jumpers are used to define the signal path configuration for the line protection circuitry. They must be set according to the specific voltage and protective sensing requirements of the site's turbine control cabinet.\u003c\/p\u003e\n\u003cp\u003eQ: Can this board be used for direct high-voltage line switching?\u003c\/p\u003e\n\u003cp\u003eA: No. The DS200LPPAG1A is a low-voltage protection and monitoring interface board designed to work with signal-level inputs from line-monitoring instrumentation. It is not intended for power-stage switching.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the Mark V rack is fully isolated and de-energized; perform mandatory lockout\/tagout procedures before handling the module.\u003c\/li\u003e\n\u003cli\u003eAlign the board with the mounting standoffs in the control cabinet, ensuring that the connector interface is parallel to the backplane to avoid pin damage.\u003c\/li\u003e\n\u003cli\u003eVerify the position of the 7 jumpers against the site wiring schematic; verify that the configuration matches the expected line protection logic.\u003c\/li\u003e\n\u003cli\u003eTerminate signal leads into the 6 available terminals (2 blocks, 3 terminals each); ensure that wire shields are grounded correctly to prevent interference.\u003c\/li\u003e\n\u003cli\u003eInspect all connections for mechanical tension and verify that terminal screws are tightened to prevent arcing under vibration.\u003c\/li\u003e\n\u003cli\u003ePerform a continuity check between the terminal block inputs and the backplane outputs to confirm signal path integrity prior to system startup.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52592704291128,"sku":"DS200LPPAG1A","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DS200LPPAG1A.jpg?v=1782892601","url":"https:\/\/www.automodulexpert.com\/products\/line-protection-board-ge-ds200lppag1a","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}