NFAR181-S00 S2 RTD Input Module Yokogawa

NFAR181-S00 S2 RTD Input Module Yokogawa
NFAR181-S00 S2 RTD Input Module Yokogawa
NFAR181-S00 S2 RTD Input Module Yokogawa
NFAR181-S00 S2 RTD Input Module Yokogawa
NFAR181-S00 S2 RTD Input Module Yokogawa
NFAR181-S00 S2 RTD Input Module Yokogawa

NFAR181-S00 S2 RTD Input Module Yokogawa

This NFAR181-S00 S2 RTD Input Module was manufactured by YOKOGAWA, In Stock, 100% Guaranteed Brand New and Authentic. Link to More Information

 
Manufacturer:
YOKOGAWA
Part Number:
NFAR181-S00 S2
Product type:
Country of Origin:
Japan
Condition:
New With Original Package
Shipping Port:
ShangHai, Xiamen
Warranty:
12 Months
 

Technical Description

The NFAR181-S00 S2 is a high-precision RTD (Resistance Temperature Detector) input module designed for Yokogawa CENTUM VP and ProSafe-RS control systems. It provides accurate temperature signal acquisition by directly interfacing with various RTD sensors, including Pt100 and JPt100 types.

As part of the FIO (Field Interface Option) I/O family, the module offers 12 input channels within a compact form factor while maintaining low power consumption and high measurement stability. The NFAR181-S00 S2 incorporates advanced signal conditioning to reduce the effects of lead-wire resistance and electromagnetic interference, ensuring consistent temperature measurements even in electrically noisy industrial environments.

The S2 suffix indicates a specific hardware revision within Yokogawa’s product lifecycle, ensuring compatibility and long-term reliability for mission-critical thermal monitoring applications.


Technical Specifications

Parameter Specification
Channel Density 12 channels per module
Supported Sensor Types Pt100, JPt100, Ni100, Cu10 RTD
Wiring Method 3-wire RTD connection (lead-wire compensation)
Conversion Accuracy ±0.1°C to ±0.2°C (depending on sensor type and range)
Isolation 1500 V AC between input channels and system bus
Data Update Cycle 100 ms for all 12 channels
Burnout Detection Detects RTD open-circuit or short-circuit faults
Operating Temperature -20°C to +70°C
Power Consumption 200 mA @ 5 V DC
Manufacturing Standard Produced in Japan under ISO quality standards
Dimensions 126 mm × 124 mm × 22 mm
Weight 0.4kg

Operational Applications

The NFAR181-S00 S2 is widely used in power generation plants, petrochemical refineries, and chemical processing facilities where precise temperature monitoring is critical to safe and efficient operation.

With its 12-channel capacity, the module is well suited for multi-point temperature monitoring, such as in reactors, distillation columns, boilers, and steam turbine systems. The built-in high-integrity isolation and signal conditioning help maintain measurement accuracy even in environments with high electrical noise or varying ground potentials.


Frequently Asked Questions

Does this module support 2-wire or 4-wire RTD sensors?
The NFAR181-S00 S2 is optimized for 3-wire RTD connections, which provide a good balance between measurement accuracy and installation cost. While 4-wire RTD sensors may be connected, the additional wire is typically not used for compensation in this configuration.

What is the significance of the S2 designation?
The S2 suffix indicates a specific hardware revision within Yokogawa’s product series. When performing maintenance or replacements, it is recommended to use the same or a compatible revision to maintain system stability.

Is the module suitable for hazardous locations?
Yes. When installed in a compatible Yokogawa FIO rack, the module typically meets international hazardous area standards, including Zone 2 or Division 2 installation requirements.

Quick Quotes Receive price & availability FAST from our dedicated customer service team.
Delivery Expedited, Freight, And International Shipping Available.
Condition 100% New with Original Package
Payment We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL.
Shipping Port ShangHai, Xiamen
Warranty 12 Months
Q: Is Our Pricing Competitive?
A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends.
Q: What Is the Warranty Period?
A: All our new and original products come with a standard one-year warranty.
Q: What Payment Methods Do We Accept?
A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them.
Q: What Shipping Methods Do We Use?
A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders.
Q: What Is Our Delivery Time?
A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule.
Q: How Do We Package the Goods?
A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes.
Q: How Can Customers Contact Us and Request a Quote?
A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote.
 

Recently Viewed

Express Shipping icon
Express Shipping
Rapid delivery for your urgent requirements.
Large stock icon
Extensive Inventory
Large stock for immediate dispatch.
Quality Assurance Icon
Quality Assurance
Authentic, top-grade PLC & DCS components.
Global Service icon
Global Service
Supporting clients worldwide with dependable service.