{"product_id":"nfcp501-w05-m01-yokogawa-stardom-fcn-cpu-module","title":"NFCP501-W05\/M01  Yokogawa STARDOM FCN CPU Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFCP501-W05\/M01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-availability processing unit engineered for the Yokogawa STARDOM FCN (Field Control Node) architecture. It serves as the intelligent core of the autonomous controller, executing complex logic control, regulatory algorithms, sequence management, and data logging tasks.\u003c\/p\u003e\n\u003cp\u003eUnlike conventional PLCs, this module combines industrial-grade controller reliability with PC-class networking capability. It supports dual-redundant Ethernet configurations, ensuring continuous operation and zero process interruption in critical control loops.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“W05”\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesignation represents a specific software license or hardware revision within the NFCP501 series, while the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“M01”\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix typically identifies the memory card or sub-module configuration. The unit mounts directly onto an FCN base module and provides high-speed backplane communication with connected I\/O modules.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU Type\u003c\/td\u003e\n\u003ctd\u003eAutonomous Controller Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eNFCP501-W05\/M01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e128 MB SDRAM (ECC supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-volatile Memory\u003c\/td\u003e\n\u003ctd\u003e128 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interfaces\u003c\/td\u003e\n\u003ctd\u003eDual 100BASE-TX \/ 10BASE-T Ethernet (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Bus Interface\u003c\/td\u003e\n\u003ctd\u003eSTARDOM FCN Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Indicators\u003c\/td\u003e\n\u003ctd\u003eHRDY, RUN, ALRM, ERR LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C (-4°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22 mm (W) × 124 mm (H) × 126 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTypical Application Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRemote Terminal Units (RTUs)\u003c\/strong\u003e\u003cbr\u003eWell-suited for oil \u0026amp; gas wellhead automation, pipeline monitoring, and remote infrastructure exposed to wide ambient temperature variations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Control Systems\u003c\/strong\u003e\u003cbr\u003eInstalled in dual configuration within FCN-RTU architectures to deliver CPU-level redundancy for critical infrastructure and continuous process operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed Process Control\u003c\/strong\u003e\u003cbr\u003eManages localized control loops in water treatment plants, renewable energy facilities, chemical processing units, and industrial automation systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NFCP501-W05\/M01 support hot-swapping?\u003c\/strong\u003e\u003cbr\u003eIn a redundant FCN configuration, the standby NFCP501-W05\/M01 can be replaced without interrupting the active controller’s operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between NFCP501 and NFCP550?\u003c\/strong\u003e\u003cbr\u003eThe NFCP501-W05\/M01 is the standard-performance CPU for FCN nodes, while the NFCP550 series typically offers enhanced processing performance or compatibility with later-generation FCN-500 hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a built-in serial port?\u003c\/strong\u003e\u003cbr\u003ePrimary communication is handled via the dual Ethernet ports. Serial communication can be implemented using dedicated FCN communication modules.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51820751749432,"sku":"NFCP501-W05\/M01","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFCP501-W05M01.jpg?v=1771983537","url":"https:\/\/www.automodulexpert.com\/products\/nfcp501-w05-m01-yokogawa-stardom-fcn-cpu-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}