{"product_id":"nfsb100-500-sbt01-yokogawa-bus-repeater-module","title":"NFSB100-500\/SBT01 YOKOGAWA Bus Repeater Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFSB100-500\/SBT01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommunication enhancement module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eregenerates and amplifies SB bus signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat have weakened over long cable runs, maintaining synchronized data exchange between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Station (FCS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand remote I\/O nodes.\u003c\/p\u003e\n\u003cp\u003eThis configuration includes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/SBT01 SB Bus T-Joint\u003c\/strong\u003e, enabling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enetwork branching\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estar-topology expansion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithout compromising signal integrity or throughput.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Operation\u003c\/td\u003e\n\u003ctd\u003eSignal regeneration and bus segment extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP SB Bus and ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Accessory\u003c\/td\u003e\n\u003ctd\u003e\/SBT01 SB Bus T-Joint for multi-drop branching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (system-powered or external)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance Latency\u003c\/td\u003e\n\u003ctd\u003eMinimal propagation delay; preserves deterministic control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–55 °C (32–131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e130 × 142.5 × 32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Protection\u003c\/td\u003e\n\u003ctd\u003eShock and vibration resistant (industrial grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eNetwork Architecture and Deployment\u003c\/h2\u003e\n\u003cp\u003eThe NFSB100-500\/SBT01 (Model:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFSB100\u003c\/strong\u003e, Suffix\/Option:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-500\/SBT01\u003c\/strong\u003e) is used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge-scale plant installations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere I\/O nodes are distributed beyond the standard SB bus distance.\u003c\/p\u003e\n\u003cp\u003eBy incorporating the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT-joint\u003c\/strong\u003e, engineers can implement\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emulti-drop and star-topology cabling\u003c\/strong\u003e, reducing overall cable requirements while maintaining\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal quality and deterministic control timing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhen is the NFSB100-500\/SBT01 required instead of a standard cable?\u003c\/strong\u003e\u003cbr\u003eA repeater is needed when\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebus cable lengths exceed SB bus limits\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor when branching a single bus line into multiple directions\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewithout signal degradation or reflections\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping?\u003c\/strong\u003e\u003cbr\u003eDisconnecting the module will\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etemporarily interrupt communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor all downstream nodes. While the hardware is robust,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaintenance must follow Yokogawa procedures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent process disruption.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51761820729656,"sku":"NFSB100-500\/SBT01","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFSB100-500SBT012.jpg?v=1770688056","url":"https:\/\/www.automodulexpert.com\/products\/nfsb100-500-sbt01-yokogawa-bus-repeater-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}