{"product_id":"node-interface-unit-yokogawa-anr10d-410","title":"Node Interface Unit Yokogawa ANR10D-410","description":"\u003ch3\u003eTechnical Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANR10D-410\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNode Interface Unit (NIU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability Yokogawa distributed control systems\u003c\/strong\u003e. It serves as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprimary gateway\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween field-level I\/O modules and the control network, providing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant ER Bus communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure continuous process data flow even in the event of a single bus failure.\u003c\/p\u003e\n\u003cp\u003eThe unit also functions as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emounting and interface hub\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor a variety of signal conditioning modules, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage, current, temperature (RTD), and pressure inputs\u003c\/strong\u003e. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompact, rack-mountable design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows seamless integration into standard marshalling cabinets within control rooms.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003eANR10D-410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Function\u003c\/td\u003e\n\u003ctd\u003eNode Interface Unit (NIU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Compatibility\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ER Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Support\u003c\/td\u003e\n\u003ctd\u003eVoltage, current, RTD, and pressure input modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transmission\u003c\/td\u003e\n\u003ctd\u003eHigh-speed throughput with real-time diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e20 W nominal (NIU only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e0°C to +55°C ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e235 mm (W) × 205 mm (H) × 110 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e1.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing Standard\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade, 24\/7 continuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Application\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANR10D-410\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge-scale industrial facilities\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical plants\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower generation stations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOffshore platforms\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt acts as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentral hub for localized I\/O clusters\u003c\/strong\u003e, simplifying\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield wiring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand enabling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentralized diagnostics\u003c\/strong\u003e. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant bus capability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emakes it the preferred choice for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efault-tolerant data acquisition\u003c\/strong\u003e, ensuring that controllers consistently receive accurate feedback from field sensors even under network stress or partial bus failure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ANR10D-410 require special software configuration?\u003c\/strong\u003e\u003cbr\u003eYes. The unit must be\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emapped in the system engineering station\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto recognize the specific I\/O modules installed in its backplane slots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the ANR10D-410 be used in non-redundant installations?\u003c\/strong\u003e\u003cbr\u003eYes, but using a single-bus configuration\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enegates the inherent fault-tolerant benefits\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovided by the dual-redundant ER Bus design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 20 W power rating inclusive of connected I\/O modules?\u003c\/strong\u003e\u003cbr\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 W rating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplies to the NIU itself. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecumulative power consumption of installed I\/O modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be added when sizing the system power supply.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51865122406712,"sku":"ANR10D-410","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ANR10D-410.jpg?v=1773020857","url":"https:\/\/www.automodulexpert.com\/products\/node-interface-unit-yokogawa-anr10d-410","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}