{"product_id":"pneumatic-differential-pressure-transmitter-13a-ms2-r-foxboro","title":"Pneumatic Differential Pressure Transmitter 13A-MS2-R Foxboro","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e13A-MS2-R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rugged\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eforce-balance pneumatic differential pressure transmitter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to convert differential pressure into a proportional pneumatic output signal. Built with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e316 stainless steel body\u003c\/strong\u003e, this 13A Series transmitter delivers long-term reliability in corrosive and harsh process environments.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eR suffix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edenotes a factory-installed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ezero suppression kit\u003c\/strong\u003e, enabling accurate calibration in applications such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eliquid level measurement in pressurized or closed vessels\u003c\/strong\u003e, where static head must be offset.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Code\u003c\/td\u003e\n\u003ctd\u003e13A-MS2-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003ePneumatic force-balance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e316 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan Limits\u003c\/td\u003e\n\u003ctd\u003eM range: 20–250 inH₂O (5–62 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e3 to 15 psi (instrument air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003e1\/2 NPT (tapped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial Feature\u003c\/td\u003e\n\u003ctd\u003eR — Zero suppression kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic Pressure Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 psi (14 MPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Weight\u003c\/td\u003e\n\u003ctd\u003e8.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Application Scenarios\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrifice Plate Flow Measurement\u003c\/strong\u003e\u003cbr\u003eMeasurement of differential pressure across primary flow elements for gas and liquid flow calculation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLiquid Level Monitoring (Closed Vessels)\u003c\/strong\u003e\u003cbr\u003eZero suppression allows compensation for static head when measuring level in pressurized tanks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Installations\u003c\/strong\u003e\u003cbr\u003eFully pneumatic operation provides safe, spark-free signal transmission in explosive environments without the need for explosion-proof electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the zero suppression kit (R option) provide?\u003c\/strong\u003e\u003cbr\u003eA: It allows the transmitter to offset a constant baseline pressure, which is essential when the transmitter is installed below the minimum liquid level in a vessel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the measurement span adjusted?\u003c\/strong\u003e\u003cbr\u003eA: Span adjustment is performed mechanically using an internal range screw. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM range\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports field calibration anywhere between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 and 250 inH₂O\u003c\/strong\u003e, offering flexibility for varying process conditions.\u003c\/p\u003e","brand":"FOXBORO","offers":[{"title":"Default Title","offer_id":51630901887288,"sku":"13AMS2","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/13AMS2.jpg?v=1768786448","url":"https:\/\/www.automodulexpert.com\/products\/pneumatic-differential-pressure-transmitter-13a-ms2-r-foxboro","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}