{"product_id":"power-supply-module-ge-ds200gdpag1ak","title":"Power Supply Module GE DS200GDPAG1AK","description":"\u003cp\u003eConfigured for high-frequency power regulation in Mark V control system platforms, the \u003cstrong\u003eGE DS200GDPAG1AK\u003c\/strong\u003e (\u003cstrong\u003eDS200GDPAG1AK\u003c\/strong\u003e High Frequency Power Supply) provides direct physical\/electrical execution. This hardware component functions as a primary power conversion unit, accepting auto-ranging AC inputs to provide a regulated 24 VDC output for downstream I\/O and logic processors. The module integrates bulk capacitance for extended hold-up and active thermal management to maintain output stability within turbine control environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200GDPAG1AK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 80 mm x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e88% efficiency at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC (47-63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (10 A continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Thermal Management\u003c\/h3\u003e\n\u003cp\u003eThe DS200GDPAG1AK utilizes internal aluminum heat sinks and a dedicated brushless fan to dissipate heat generated during high-frequency switching. The internal architecture facilitates backplane bus communication velocity by ensuring a clean, ripple-free power rail (\u0026lt;50 mV peak-to-peak), which is required for sensitive control logic stability. Firmware flash compatibility is not applicable, as this is a power conversion unit; however, it interfaces with system monitoring circuits to report status and fault conditions through the designated control signal connector.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the DS200GDPAG1AK be operated without the internal brushless fan?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal fan is required for active cooling of the power semiconductor stages. Operating the unit without functional airflow will result in premature thermal shutdown and potential long-term damage to the internal PCB components.\u003c\/p\u003e\n\u003cp\u003eQ: How does the 3-second hold-up time affect system operation?\u003c\/p\u003e\n\u003cp\u003eA: The 6800 µF bulk capacitance bank allows the unit to maintain output voltage for 3 seconds following an input AC loss, providing sufficient time for the control system to perform an orderly emergency shutdown or transition to a redundant supply.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the Mark V cabinet power is isolated and verified using LOTO procedures.\u003c\/li\u003e\n\u003cli\u003eInstall the unit in an orientation that allows for unobstructed airflow through the cooling fan intake and exhaust ports.\u003c\/li\u003e\n\u003cli\u003eTerminate the AC input leads to the input terminal block, ensuring proper gauge wiring to support 10 A continuous load.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 VDC output connections to the control bus; ensure polarity is correct before energizing the module.\u003c\/li\u003e\n\u003cli\u003eConnect the control signal interface to the system monitoring port to enable remote fault detection.\u003c\/li\u003e\n\u003cli\u003eOnce power is applied, verify the output voltage at the terminals using a calibrated digital multimeter before connecting critical I\/O loads.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52614135316792,"sku":"DS200GDPAG1AK","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DS200GDPAG1ALF_1.jpg?v=1731054415","url":"https:\/\/www.automodulexpert.com\/products\/power-supply-module-ge-ds200gdpag1ak","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}