{"product_id":"pr6423-016-000-pr6423-emerson-eddy-current-displacement-sensor","title":"PR6423\/016-000 PR6423 Emerson Eddy Current Displacement Sensor","description":"\u003ch2\u003eEmerson PR6423\/016-000 Eddy Current Displacement Sensor\u003c\/h2\u003e\n\u003cp\u003eThe Emerson \u003cstrong\u003ePR6423\/016-000\u003c\/strong\u003e is a non-contact eddy current displacement sensor designed to measure shaft vibration, axial displacement, and rotor position on rotating machinery when paired with a compatible signal converter such as CON011 or CON021. Source notes list a stainless-steel housing, IP66 protection rating, -35 deg C to +180 deg C operating temperature, and 8 V\/mm sensitivity, while probe diameter is cited as 16 mm in the overview and 8 mm in the specification table.\u003c\/p\u003e\n\u003ch3\u003eSensing Operation and Signal Output\u003c\/h3\u003e\n\u003cp\u003eNon-contact eddy current probes generate an electromagnetic field at the sensing tip and detect changes in gap distance relative to a conductive metal target surface without mechanical wear. When connected to a compatible converter such as CON011 or CON021, the assembly outputs a conditioned signal for shaft vibration, radial or axial displacement, and position monitoring.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Ranges:\u003c\/strong\u003e Specifications list a +- 1.0 mm static measuring range, 0-500 um dynamic measuring range, and 1.5 mm nominal measuring gap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity and Linearity:\u003c\/strong\u003e Rated at 8 V\/mm sensitivity with linearity error less than or equal to +- 1% after calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget and Termination:\u003c\/strong\u003e Built with a stainless-steel housing for conductive steel targets and uses a LEMO connector for converter connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThermal Ratings and Source Discrepancies\u003c\/h3\u003e\n\u003cp\u003eThe sensor is rated for continuous operation from -35 deg C to +180 deg C, with short-term exposure up to +200 deg C and an IP66 protection rating noted in the overview. Because one source entry lists a 16 mm probe diameter while the technical specification table lists an 8 mm sensor diameter, verify the physical tip diameter and \/016-000 suffix configuration before ordering.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Limits:\u003c\/strong\u003e Rated for -35 deg C to +180 deg C operating temperature and up to +200 deg C short-term exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiameter Discrepancy:\u003c\/strong\u003e Confirm whether your mounting bracket requires an 8 mm or 16 mm probe diameter and check \/016-000 configuration details against your bill of materials.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/016-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson (EPRO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy Current Displacement Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eNon-contact eddy-current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic Measuring Range\u003c\/td\u003e\n\u003ctd\u003e+- 1.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Measuring Range\u003c\/td\u003e\n\u003ctd\u003e0-500 um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Measuring Gap\u003c\/td\u003e\n\u003ctd\u003e1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e8 V\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to +- 1% (after calibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eElectrically conductive steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Connection\u003c\/td\u003e\n\u003ctd\u003eLEMO connector for compatible converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Converters\u003c\/td\u003e\n\u003ctd\u003eCON011 \/ CON021 and compatible EPRO systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +180 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Term Temperature\u003c\/td\u003e\n\u003ctd\u003eUp to +200 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Which signal converters are listed as compatible with the PR6423\/016-000 sensor? A: The specification table lists compatibility with CON011, CON021, and compatible EPRO systems using a LEMO connection. Confirm converter calibration and input scaling match your monitoring channel before installation.\u003c\/p\u003e\n\u003cp\u003eQ: Why do the source notes mention both 16 mm and 8 mm probe\/sensor diameters? A: The overview text refers to a 16 mm eddy current displacement sensor, whereas the technical specification table lists an 8 mm sensor diameter. Verify the physical probe tip size and \/016-000 configuration details before procurement.\u003c\/p\u003e\n\u003cp\u003eQ: What temperature and target material specifications apply to the PR6423\/016-000? A: Specifications list electrically conductive steel targets, -35 deg C to +180 deg C operating temperature, and short-term tolerance up to +200 deg C. Check probe-tip ambient conditions and target material properties during commissioning.\u003c\/p\u003e","brand":"EPRO","offers":[{"title":"Default Title","offer_id":51483804172600,"sku":"PR6423\/016-000","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/CON021_PR6426000-1102.jpg?v=1765157825","url":"https:\/\/www.automodulexpert.com\/products\/pr6423-016-000-pr6423-emerson-eddy-current-displacement-sensor","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}