{"product_id":"safe-digital-output-relay-module-honeywell-fs-tsro-0824","title":"Safe Digital Output Relay Module | Honeywell FS-TSRO-0824","description":"\u003ch2\u003eHoneywell FS-TSRO-0824 Digital Output Relay FTA\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-TSRO-0824\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTSRO-0824\u003c\/strong\u003e Digital Output (Relay) Field Termination Assembly, operates as a dedicated hardware component for relay-based contact execution within Honeywell FSC and Safety Manager platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-TSRO-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e300 mm x 70 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypically 40 mA at 24 VDC (0.96 W nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 relay contact outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Voltage\u003c\/td\u003e\n\u003ctd\u003e36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Pick-up Voltage\u003c\/td\u003e\n\u003ctd\u003e19.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switched Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC \/ 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switched Load\u003c\/td\u003e\n\u003ctd\u003e1250 VA \/ 150 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e5 A per channel (fused)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Output Current\u003c\/td\u003e\n\u003ctd\u003e1 mA at 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003e5 A slow-acting fuse (5 x 20 mm) per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Relay Loop Execution\u003c\/h3\u003e\n\u003cp\u003eThe field termination assembly routes control signals through 8 electro-mechanical relay circuits, converting internal 24 VDC driving logic into isolated high-capacity switching paths. Galvanic isolation between drive electronics and field relay contacts protects system backplane components against field-side electrical transients. Integrated status LEDs provide channel-level optical verification during state switching. Individual 5 A slow-acting fuses defend against overcurrent conditions, maintaining loop integrity across SIL 3 safety instrumented functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the maximum switching voltage and load limits for the relay channels?\u003c\/p\u003e\n\u003cp\u003eA: Each channel supports up to 250 VAC or 250 VDC, handling a maximum switched power load of 1250 VA (AC) or 150 W (DC).\u003c\/p\u003e\n\u003cp\u003eQ: How are short-circuit conditions on individual field outputs contained?\u003c\/p\u003e\n\u003cp\u003eA: Each output channel integrates an onboard 5 A slow-acting fuse (5 x 20 mm) that isolates overcurrent faults without compromising adjacent relay loops.\u003c\/p\u003e\n\u003cp\u003eQ: Which DIN-rail standard accommodates physical installation of the FTA?\u003c\/p\u003e\n\u003cp\u003eA: The module mounts directly onto TS32 or TS35 x 7.5 mm DIN rails, occupying approximately 301 mm of total rail length.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the assembly securely onto the DIN rail inside an earthed enclosure before making field terminations. Strip incoming field conductors to exactly 7 mm and secure them into screw terminals using a calibrated torque driver set to 0.5 Nm. Route AC\/DC load cabling separately from low-voltage logic signal wiring to prevent electromagnetic cross-talk. Connect all cable shields to the main panel grounding bus.\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":53303125934392,"sku":"FS-TSRO-0824","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/632..jpg?v=1792200143","url":"https:\/\/www.automodulexpert.com\/products\/safe-digital-output-relay-module-honeywell-fs-tsro-0824","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}