{"product_id":"safety-analog-input-module-ge-8810-hi-tx","title":"Safety Analog Input Module GE 8810-HI-TX","description":"\u003cp\u003eThe \u003cstrong\u003eGE 8810-HI-TX\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8810-HI-TX\u003c\/strong\u003e Safety Analog Input Module, operates as a dedicated hardware component for 4-20 mA current loop signal acquisition within FB-8800 Safety Logic Solver platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8810-HI-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eSingle Ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFail-Safe State Execution and Galvanic Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 8810-HI-TX module is engineered for high-integrity safety instrumented systems, incorporating internal diagnostic features to ensure fail-safe state execution. Each of the eight input channels provides galvanic isolation, which prevents electrical faults from propagating through the safety backplane and ensures loop integrity during common-mode transients. The module continuously monitors for out-of-range current values, automatically transitioning to a predefined safe state upon detection of a loop break or signal failure to maintain the safety shutdown logic of the FB-8800 controller.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module be configured for redundant input sensing?\u003c\/p\u003e\n\u003cp\u003eA: The module supports 8-channel input handling. For redundancy, multiple modules may be utilized in parallel or series configurations depending on the specific safety logic requirements defined in the FB-8800 safety configuration software.\u003c\/p\u003e\n\u003cp\u003eQ: What is the required current loop resistance for optimal performance?\u003c\/p\u003e\n\u003cp\u003eA: The input circuitry is designed for standard 4-20 mA loop impedance. Ensure the external loop load does not exceed the voltage drop limitations specified for the FB-8800 backplane power supply to maintain accurate current measurement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the FB-8800 safety logic solver is de-energized before mounting the 8810-HI-TX module into the chassis to avoid electrical arching on the backplane connector.\u003c\/li\u003e\n\u003cli\u003eTerminate 4-20 mA input signals using shielded, twisted-pair cabling. The shield should be grounded only at the safety barrier or distribution point to mitigate noise coupling.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is fully latched into the rack. Loose connections can cause signal fluctuations that may be interpreted by the safety solver as an out-of-range fault condition.\u003c\/li\u003e\n\u003cli\u003eKeep signal wiring separated from high-voltage power conduits by a minimum distance of 200 mm to maintain electromagnetic compatibility (EMC) standards.\u003c\/li\u003e\n\u003cli\u003ePerform a loop check after wiring to verify that the 4 mA and 20 mA signals are correctly interpreted by the safety solver logic.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52649406234936,"sku":"8810-HI-TX","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/8810-HI-TX2.jpg?v=1784189484","url":"https:\/\/www.automodulexpert.com\/products\/safety-analog-input-module-ge-8810-hi-tx","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}