{"product_id":"sat145-s63-prp-s2-yokogawa-thermocouple-input-module","title":"SAT145-S63\/PRP S2 Yokogawa Thermocouple Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSAT145-S63\/PRP S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP Distributed Control System (DCS)\u003c\/strong\u003e. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 isolated input channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoptimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouple and low-level millivolt (mV) signals\u003c\/strong\u003e, making it an essential component for high-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etemperature monitoring and process control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module supports a wide range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouple types and mV inputs\u003c\/strong\u003e, enabling accurate acquisition of temperature measurements in complex industrial environments. With\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed data processing and advanced isolation protection\u003c\/strong\u003e, the SAT145-S63\/PRP S2 ensures stable and reliable signal conditioning for critical process instrumentation.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePRP (Parallel Redundancy Protocol)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenhancement allows the module to operate within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant dual-network architectures\u003c\/strong\u003e, ensuring continuous communication and eliminating single points of failure. Designed for harsh industrial environments, the hardware is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISA S71.04 G3 compliant\u003c\/strong\u003e, providing resistance to corrosive atmospheric contaminants and maintaining stable operation across a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewide temperature range of −20°C to 70°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSAT145-S63\/PRP S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Refresh Rate\u003c\/td\u003e\n\u003ctd\u003e40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±10 µV or ±0.01% depending on configured range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 MΩ minimum (power-on); 10 kΩ (power-off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1.5 kV AC between input signals and system logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coating compliant with ISA S71.04 G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−20°C to 70°C (−4°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eComparison with SAT145-S53\u003c\/h3\u003e\n\u003cp\u003eCompared with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSAT145-S53\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSAT145-S63\/PRP S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended operating temperature range\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuitable for extreme environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePRP network support\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor dual redundant communication paths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImproved compatibility with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability CENTUM VP architectures\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhile both modules support\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 thermocouple\/mV channels\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS63 version\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically selected for installations requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eenhanced environmental resilience and advanced network redundancy\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSAT145-S63\/PRP S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in industries requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecise temperature measurement and high system availability\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical and chemical processing plants\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower generation facilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil and gas production systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRefining and heavy industrial process units\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypical monitoring applications include\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereactor temperature measurement, furnace monitoring, heat exchanger control, and turbine temperature supervision\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific terminal block for thermocouple inputs?\u003c\/strong\u003e\u003cbr\u003eYes. To utilize\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal Reference Junction Compensation (RJC)\u003c\/strong\u003e, the module should be paired with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompatible pressure clamp terminal block that includes an integrated temperature sensor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eIn a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant CENTUM VP system configuration\u003c\/strong\u003e, the SAT145-S63\/PRP S2 can be replaced while the system remains online. However, proper maintenance procedures and safety guidelines should always be followed to avoid process disturbances.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51894672326968,"sku":"SAT145-S63\/PRP S2","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/SAI533-H03A4S001.jpg?v=1773628581","url":"https:\/\/www.automodulexpert.com\/products\/sat145-s63-prp-s2-yokogawa-thermocouple-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}