{"product_id":"thermocouple-input-module-foxboro-fbm2-p0400yc","title":"Thermocouple Input Module | Foxboro FBM2 P0400YC","description":"\u003ch1 data-path-to-node=\"0\" class=\"\"\u003eFoxboro FBM2 P0400YC Thermocouple Input Module\u003c\/h1\u003e\n\u003cp data-path-to-node=\"1\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eFoxboro FBM2 P0400YC\u003c\/b\u003e\u003cspan\u003e (also designated as FBM02) is an eight-channel thermocouple and millivolt input interface module for the Foxboro I\/A Series distributed control system.\u003c\/span\u003e\u003cspan\u003e It acquires low-level signals from field thermocouples and millivolt sources,\u003c\/span\u003e\u003cspan\u003e converting them into digital process data for system monitoring and temperature control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eSignal Processing and Channel Isolation\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan\u003eThe module provides eight isolated input channels alongside a dedicated isolated channel for reference junction compensation,\u003c\/span\u003e\u003cspan\u003e using a 100 Ohm platinum RTD sensor to ensure accurate temperature measurements.\u003c\/span\u003e\u003cspan\u003e It accepts input signal ranges from approximately -10.\u003c\/span\u003e\u003cspan\u003e5 to +71.\u003c\/span\u003e\u003cspan\u003e41875 mV DC,\u003c\/span\u003e\u003cspan\u003e accommodating standard thermocouple types B,\u003c\/span\u003e\u003cspan\u003e E,\u003c\/span\u003e\u003cspan\u003e J,\u003c\/span\u003e\u003cspan\u003e K,\u003c\/span\u003e\u003cspan\u003e N,\u003c\/span\u003e\u003cspan\u003e S,\u003c\/span\u003e\u003cspan\u003e T,\u003c\/span\u003e\u003cspan\u003e and direct millivolt sources.\u003c\/span\u003e\u003cspan\u003e Galvanic channel isolation suppresses ground loops and electrical noise during long cable runs in complex industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,1,0\"\u003eFBM2 P0400YC (FBM02)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,1,0\"\u003eFoxboro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,0,0\"\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,1,0\"\u003eThermocouple \/ mV Input Interface Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,0,0\"\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,1,0\"\u003e8 isolated input channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,0,0\"\u003eReference Junction Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,1,0\"\u003e1 isolated channel (100 Ohm platinum RTD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,0,0\"\u003eSupported Input Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,1,0\"\u003eThermocouples (Types B, E, J, K, N, S, T) and mV signals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,0,0\"\u003eInput Signal Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,1,0\"\u003e-10.5 to +71.41875 mV DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,1,0\"\u003eUp to 9 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,9,0,0\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,9,1,0\"\u003e0 deg C to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,10,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,10,1,0\"\u003e1.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,11,0,0\"\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,11,1,0\"\u003eFoxboro I\/A Series FBM baseplate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What thermocouple sensor types are compatible with the FBM2 P0400YC?\u003c\/span\u003e\u003cspan\u003e A:\u003c\/span\u003e\u003cspan\u003e The module supports thermocouple types B,\u003c\/span\u003e\u003cspan\u003e E,\u003c\/span\u003e\u003cspan\u003e J,\u003c\/span\u003e\u003cspan\u003e K,\u003c\/span\u003e\u003cspan\u003e N,\u003c\/span\u003e\u003cspan\u003e S,\u003c\/span\u003e\u003cspan\u003e and T,\u003c\/span\u003e\u003cspan\u003e as well as direct millivolt DC signal sources.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e How does the module handle cold junction compensation for temperature readings?\u003c\/span\u003e\u003cspan\u003e A:\u003c\/span\u003e\u003cspan\u003e It features a dedicated isolated reference junction channel that utilizes a 100 Ohm platinum RTD sensor for compensation.\u003c\/span\u003e\u003c\/p\u003e","brand":"FOXBORO","offers":[{"title":"Default Title","offer_id":51300134715704,"sku":"FBM2 P0400YC","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/FBM2_P0400YC2_16993264-0feb-415b-ab54-96d2846c4c3b.jpg?v=1761891018","url":"https:\/\/www.automodulexpert.com\/products\/thermocouple-input-module-foxboro-fbm2-p0400yc","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}