{"product_id":"transistor-contact-output-module-adm51-2-ce1-yokogawa","title":"Transistor Contact Output Module ADM51-2\/CE1 Yokogawa","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADM51C-2\/CE1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision discrete output module designed for the Yokogawa Electric Corporation CENTUM CS 3000 and CENTUM CS 1000 legacy control platforms.\u003c\/p\u003e\n\u003cp\u003eThis module provides solid-state transistor-based discrete outputs for controlling field devices such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSolenoid valves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmall relay coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndicator lamps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterposing control circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe transistor output design eliminates mechanical wear associated with relay contacts, enabling high-speed switching and extended service life. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CE1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix indicates compliance with enhanced electromagnetic compatibility and European regulatory standards.\u003c\/p\u003e\n\u003cp\u003eThe ADM51C-2\/CE1 supports multiple control signal modes including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous status signaling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePulse-based actuation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne-shot timing control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTime-proportional duty cycle control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis makes the module suitable for both simple discrete control and advanced sequence logic applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Model\u003c\/td\u003e\n\u003ctd\u003eADM51C-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Suffix\u003c\/td\u003e\n\u003ctd\u003e\/CE1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003e16 or 32 isolated transistor outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Capacity\u003c\/td\u003e\n\u003ctd\u003e30 V DC max100 mA per channel (resistive or inductive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic-Side Power\u003c\/td\u003e\n\u003ctd\u003e600 mA max at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003e0.1 s – 7200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Resolution\u003c\/td\u003e\n\u003ctd\u003e20 ms increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Modes\u003c\/td\u003e\n\u003ctd\u003eStatus OutputPulse OutputOne-Shot PulseTime Proportional Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Interface\u003c\/td\u003e\n\u003ctd\u003eDirect DCS rack bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Technology\u003c\/td\u003e\n\u003ctd\u003eSolid-state transistor outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSolenoid and Valve Control\u003c\/strong\u003e\u003cbr\u003eProvides fast, reliable switching for pneumatic and hydraulic control valves.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Interlock Systems\u003c\/strong\u003e\u003cbr\u003eDrives intermediate relay stages in safety logic architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperator Signaling\u003c\/strong\u003e\u003cbr\u003eControls alarm panels, stack lights, and local HMI indicators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Timing Sequences\u003c\/strong\u003e\u003cbr\u003eSupports pulse-based batch sequencing and PID duty-cycle modulation.\u003c\/p\u003e\n\u003cp\u003eThe solid-state architecture is particularly advantageous in environments where contact wear, arcing, or mechanical degradation must be minimized.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does transistor output differ from relay output?\u003c\/strong\u003e\u003cbr\u003eTransistor outputs provide semiconductor switching with very fast response times and extremely high switching cycle life. However, they are limited to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC loads within 100 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand cannot directly switch high-voltage AC circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan pulse width settings be adjusted after installation?\u003c\/strong\u003e\u003cbr\u003eYes. Pulse timing parameters (0.1 s to 7200 s) are configurable via the CENTUM CS 3000 or CS 1000 engineering station software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module suitable for inductive loads?\u003c\/strong\u003e\u003cbr\u003eYes, but proper suppression measures (such as flyback diodes) should be implemented when driving inductive field devices.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51818402677048,"sku":"ADM51-2\/CE1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADM51-2CE11.jpg?v=1771898191","url":"https:\/\/www.automodulexpert.com\/products\/transistor-contact-output-module-adm51-2-ce1-yokogawa","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}