{"product_id":"ur-6av-digital-i-o-module-general-electric","title":"UR 6AV Digital I\/O Module General Electric","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric UR 6AV\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e6AV\u003c\/strong\u003e Digital I\/O module, operates as a dedicated hardware component for high-density discrete signal acquisition and control execution within Multilin Universal Relay (UR) platforms. This module provides 8 digital inputs for field status monitoring and incorporates 6 A output contact capacity for localized control switching.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR 6AV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.88 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard UR module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on input\/output state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rating\u003c\/td\u003e\n\u003ctd\u003e6 A contact capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eMultilin Universal Relay (UR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe UR 6AV module communicates via the relay backplane bus to ensure real-time synchronization between external discrete devices and the host processor. The integration of 8 digital input channels facilitates rapid state detection, while the 6 A output relay contacts provide the necessary current capacity for direct control of auxiliary devices or annunciation circuits. Technical personnel must ensure that the relay system firmware recognizes the 6AV module configuration to maintain precise I\/O scan timing within the protective logic matrix.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the 8 digital inputs isolated from the backplane circuitry?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The input channels feature internal isolation to prevent field-side transients or common-mode noise from propagating into the UR internal processor and backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 6 A output contacts be used for high-voltage switching?\u003c\/p\u003e\n\u003cp\u003eA: While the contacts are rated for 6 A current, they must be used within the voltage limits specified for the UR relay platform. Refer to the specific control wiring diagrams to ensure inductive flyback protection is utilized for any DC load switching.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the Multilin UR chassis power is completely isolated before installation.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the chassis slot guide rails to avoid pin stress or misalignment with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eSlide the module forward until the rear connector is fully seated, then secure the front-panel captive screws.\u003c\/li\u003e\n\u003cli\u003eTerminate digital input leads to the specified terminal blocks, ensuring correct polarity.\u003c\/li\u003e\n\u003cli\u003eConnect output control circuits to the 6 A relay contact terminals, verifying appropriate wire sizing for the load current.\u003c\/li\u003e\n\u003cli\u003eUse the front-panel interface to perform a self-test of the 8 input channels and verify the functional response of the output contacts before putting the relay into service.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52620207620408,"sku":"UR 6AV","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR6AV.jpg?v=1760160631","url":"https:\/\/www.automodulexpert.com\/products\/ur-6av-digital-i-o-module-general-electric","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}