{"product_id":"ur-6tv-ge-multilin-universal-relay-digital-io-module","title":"UR-6TV GE Multilin Universal Relay Digital IO Module","description":"\u003ch2\u003eGE UR-6TV Multilin Universal Relay Digital I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE UR-6TV\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eUR-6TV\u003c\/strong\u003e Digital I\/O Module, operates as a dedicated hardware component for digital input monitoring and Form-A contact output execution within GE Multilin Universal Relay platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR-6TV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ GE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndustrial Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.24 cm x 17.78 cm x 3.81 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane Auxiliary Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e8 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e4 Form-A Relay Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eSelf-Check Diagnostics and LED Status Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Interface\u003c\/td\u003e\n\u003ctd\u003eEnerVista UR Setup Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eInternal Backplane Bus \/ Modbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Communication \u0026amp; System Integration\u003c\/h3\u003e\n\u003cp\u003eEngineers deploy the module into Universal Relay subrack platforms to process digital status inputs and drive high-speed trip contacts across substation protection schemes. Furthermore, internal circuit optimization maximizes backplane bus communication velocity during concurrent input acquisition and relay switching cycles. Consequently, system integrators expand overall I\/O channel density without degrading signal execution speed or introducing bus arbitration delays. In addition, full firmware flash compatibility guarantees synchronized operational logic execution across EnerVista configuration software environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How do the integrated diagnostic features report module hardware status?\u003c\/p\u003e\n\u003cp\u003eA: Internal self-check routines monitor internal supply rails and processor heartbeats, driving front-panel LED indicators and flagging backplane fault alarms if a failure occurs.\u003c\/p\u003e\n\u003cp\u003eQ: What contact rating and behavior do the 4 Form-A outputs exhibit?\u003c\/p\u003e\n\u003cp\u003eA: The outputs function as normally open dry contacts designed for fast, high-current trip circuit execution within protection schemes.\u003c\/p\u003e\n\u003cp\u003eQ: Is software configuration required when inserting a replacement card into an active UR chassis?\u003c\/p\u003e\n\u003cp\u003eA: Yes, slot identification addresses and output logic mapping must be configured via EnerVista UR software to re-establish backplane communication.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFirst, technicians must isolate auxiliary power supply feeds to the host relay chassis before inserting or removing the hardware card. Next, align the module circuit card guides carefully with the subrack slot tracks and slide the assembly inward until the backplane multi-pin interface seats fully. Tighten both front panel retention screws securely to maintain mechanical frame grounding and resist high-vibration field conditions. Furthermore, route all external digital input and contact output cables using shielded twisted pairs separated from primary AC power conductors to suppress electromagnetic noise coupling. Finally, check all terminal block screw connections and verify LED status indications after restoring auxiliary power to the relay unit.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51225153634616,"sku":"UR6TV","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/UR6CH.jpg?v=1760160632","url":"https:\/\/www.automodulexpert.com\/products\/ur-6tv-ge-multilin-universal-relay-digital-io-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}