{"product_id":"v-net-interface-card-yokogawa-centum-cs-3000-sb301-s1","title":"V-net Interface Card Yokogawa CENTUM CS 3000 SB301-S1","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSB301-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance communication interface card specifically engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM CS 3000 Distributed Control System (DCS)\u003c\/strong\u003e. Serving as a critical bridge within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eV-net communication layer\u003c\/strong\u003e, this card facilitates the high-speed data exchange necessary for real-time process monitoring and control. It is designed to be installed within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Station (FCS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor relevant bus interface units to ensure seamless connectivity between the control processors and the supervisory network.\u003c\/p\u003e\n\u003cp\u003eAs a core component of the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einfrastructure, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSB301-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built to maintain the deterministic data throughput required for mission-critical automation. Although the series has entered its maintenance lifecycle, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSB301-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eremains an indispensable spare part for facilities prioritizing the longevity and stability of their existing control assets. Its robust PCB design is optimized for continuous 24\/7 operation in industrial environments such as power plants and chemical refineries.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV-net Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS1 (Proprietary Yokogawa Bus Interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCard Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC Board \/ Add-on Communication Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptimized for V-net real-time throughput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Topology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports dual-redundant V-net configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS1 (Designates specific component compatibility)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C (Standard cabinet environment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.36 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eMaintenance and Lifecycle Value\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSB301-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a key asset for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLifecycle Management (LCM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estrategies. For plants currently operating on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform, maintaining a stock of these interface cards is vital to preventing extended downtime during network hardware failures. This card ensures that legacy systems can continue to perform complex data acquisition without requiring a complete and costly migration to newer DCS generations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: Is the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSB301-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecompatible with the newer\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Vnet\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enetwork?\u003cbr\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: No. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSB301-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for the traditional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eV-net bus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. Migration to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically requires newer interface hardware such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVF701\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor equivalent modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: Does this card support redundancy?\u003cbr\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: Yes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSB301-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis fully compatible with redundant\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eV-net\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitectures. In most critical installations, two cards are used in tandem to ensure the control network remains functional if one card fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51847096860984,"sku":"SB301 S1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/SB301_S11.jpg?v=1772417010","url":"https:\/\/www.automodulexpert.com\/products\/v-net-interface-card-yokogawa-centum-cs-3000-sb301-s1","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}