{"product_id":"woodward-8200-1301-rev-t-digital-governor-for-steam-turbines","title":"Woodward 8200-1301 REV.T Digital Governor for Steam Turbines","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 8200-1301 REV.T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an essential component of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e505 Digital Control Series\u003c\/strong\u003e, specifically designed to manage the operation of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle-valve\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efollowed-valve steam turbines\u003c\/strong\u003e. This microprocessor-based governor offers precise control over\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbine speed\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eload\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eextraction headers\u003c\/strong\u003e, ensuring deterministic performance. It serves as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estand-alone control solution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial steam turbines\u003c\/strong\u003e, featuring an integrated operator interface panel and advanced software for comprehensive\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emachine protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8200-1301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRevision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eREV.T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% Brand New and Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e505 Digital Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteam Turbine Speed and Load Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Front-Panel Vacuum Fluorescent Display (VFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiple Magnetic Pickup (MPU) and Proximity Probe inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA Actuator and Readout Signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Governing Logic\u003c\/strong\u003e: The 8200-1301 REV.T uses high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePID algorithms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto eliminate frequency hunting, ensuring stable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbine speed\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeven under\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esevere steam header pressure fluctuations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor sudden\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eload rejections\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Operator Control Panel (OCP)\u003c\/strong\u003e: The rugged\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efront-panel keypad\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edisplay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenable real-time tuning, startup sequencing, and manual overrides, eliminating the need for external laptops or HMIs on the turbine skid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Turbine Protection\u003c\/strong\u003e: Includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoverspeed protection\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecritical speed avoidance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(skip frequencies), and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estartup rate limiting\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto safeguard against catastrophic failure during transient operating conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable Multi-Function I\/O\u003c\/strong\u003e: Offers a variety of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog and discrete I\/O points\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat can be mapped to specific turbine functions, allowing for integration with auxiliary systems like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elube oil pressure interlocks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egenerator breaker status\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRevision T Hardware Stability\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eREV.T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesignation signifies the latest hardware upgrades for enhanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectromagnetic compatibility (EMC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal resilience\u003c\/strong\u003e, ensuring reliable performance in high-vibration and high-heat environments typical of steam turbine enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003ch4\u003eIs this Woodward 8200-1301 REV.T module a brand new unit?\u003c\/h4\u003e\n\u003cp\u003eYes, we supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoriginal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWoodward\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8200-1301 REV.T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egovernors in factory-sealed packaging, ensuring full operational integrity and manufacturer compliance.\u003c\/p\u003e\n\u003ch4\u003eCan the 8200-1301 manage extraction steam turbines?\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8200-1301\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle-valve turbines\u003c\/strong\u003e. For more complex\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eextraction\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eadmission turbines\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erecommends the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e505E variant\u003c\/strong\u003e. Always verify the turbine’s specific valve configuration before installation.\u003c\/p\u003e\n\u003ch4\u003eWhat is the primary benefit of the REV.T update?\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eREV.T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eupdate provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eimproved component reliability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand enhanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efirmware compatibility\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith modern communication protocols. It ensures the hardware meets the latest industrial standards, especially for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enoise immunity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein high-voltage power plant environments.\u003c\/p\u003e\n\u003ch4\u003eHow do I configure the speed setpoints for a new installation?\u003c\/h4\u003e\n\u003cp\u003eEngineers can easily configure speed setpoints using the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efront-panel \"Configure\" mode\u003c\/strong\u003e. This menu-driven interface guides users through turbine-specific parameters (such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egear tooth count\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eidle speed\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erated speed\u003c\/strong\u003e) without the need for specialized programming languages.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":52036070900024,"sku":"8200-1301 REV.T","price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/8200-1301_REV.T.jpg?v=1775534408","url":"https:\/\/www.automodulexpert.com\/products\/woodward-8200-1301-rev-t-digital-governor-for-steam-turbines","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}