{"product_id":"yokogawa-aap135-s50-13s00-pulse-input-module","title":"Yokogawa AAP135-S50\/13S00 Pulse Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAP135-S50\/13S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision pulse input module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFIO (Field Interface I\/O)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecomponent is specifically designed to interface with field devices that generate pulse train signals, such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflowmeters (turbine, vortex, or magnetic)\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed sensors\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edisplacement encoders\u003c\/strong\u003e. With\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 independent channels\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAP135-S50\/13S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverts high-frequency pulses into digitized data for precise flow accumulation, velocity measurement, and frequency monitoring within the control logic.\u003c\/p\u003e\n\u003cp\u003eEach channel on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAP135-S50\/13S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis capable of handling a wide range of pulse frequencies and signal types, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edry contact\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage pulses\u003c\/strong\u003e. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/13S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration identifies the specific terminal block and environmental coating version, ensuring compatibility with standard FIO node units while providing enhanced protection against industrial atmospheric contaminants.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-channel isolated pulse input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact (Dry), Voltage Pulse (Pulse width ≥ 10 μs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz to 10 kHz (High-speed pulse capture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1% of set range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividual channel-to-system isolation (withstand 500 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in digital filtering to eliminate contact bounce\/chatter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 A at 5 V DC (Internal system power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAAP135-S50\/13S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSlot-compatible with Yokogawa ANB10 and ANB11 node units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuitable for SIL 2\/3 applications when used in ProSafe-RS nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAP135-S50\/13S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis utilized in critical industrial measurement loops, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePrecision custody transfer for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil and gas flow measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTurbine speed monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand overspeed protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBatch control systems requiring high-speed pulse accumulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: Can the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAP135-S50\/13S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandle inputs from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNAMUR-type sensors\u003c\/strong\u003e?\u003cbr\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: While primarily designed for standard voltage and contact pulses, this module can interface with various sensor types via external signal conditioners if NAMUR-level signals are required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: What is the maximum distance the pulse signal can travel to this module?\u003cbr\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: The distance depends on cable capacitance and signal frequency. For high-frequency pulses (up to 10 kHz),\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshielded twisted-pair cables\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare recommended to minimize signal attenuation and noise interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51847097057592,"sku":"AAP135-S50\/13S00","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AAP135-S5013S00.jpg?v=1772417010","url":"https:\/\/www.automodulexpert.com\/products\/yokogawa-aap135-s50-13s00-pulse-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}