{"product_id":"yokogawa-aav144-s53-k4a00-analog-input-module","title":"Yokogawa AAV144-S53\/K4A00 Analog Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAV144-S53\/K4A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP distributed control system\u003c\/strong\u003e. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 fully isolated channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor accurate acquisition of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA process signals\u003c\/strong\u003e, supporting high-density signal monitoring in industrial control cabinets.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS53 suffix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edenotes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandard module with conformal coating (ISA G3 compliant)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor enhanced protection against corrosive gases and harsh atmospheric conditions. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eK4A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesignation identifies the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eterminal block or connector configuration\u003c\/strong\u003e, ensuring compatibility with specific wiring terminations. With high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 ms data refresh\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand ±0.1% full-scale accuracy, the module ensures precise and reliable signal acquisition for critical control loops.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Code\u003c\/td\u003e\n\u003ctd\u003eAAV144-S53\/K4A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input (16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eIndividual channel-to-system isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Refresh Rate\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coating (S53), ISA G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 V DC @ 450 mA (backplane supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe AAV144-S53\/K4A00 is widely used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical process control applications\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas production facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt monitors process variables such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure, flow, temperature (via transmitters), and level\u003c\/strong\u003e, while the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel high-density layout\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoptimizes cabinet space and wiring efficiency.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the \/K4A00 suffix indicate?\u003c\/strong\u003e\u003cbr\u003eIt specifies the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eterminal block or connector configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof the module, ensuring compatibility with particular wiring termination styles in the control cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the AAV144-S53\/K4A00 support redundancy?\u003c\/strong\u003e\u003cbr\u003eYes. Modules can be installed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant pairs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin CENTUM VP FIO nodes, enabling uninterrupted signal acquisition even if one module fails.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51746640429368,"sku":"AAV144 -S53 \/K4A00","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AAV144-S00.jpg?v=1763018897","url":"https:\/\/www.automodulexpert.com\/products\/yokogawa-aav144-s53-k4a00-analog-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}