{"product_id":"yokogawa-adm11-ce1-contact-input-module","title":"Yokogawa ADM11\/CE1 Contact Input Module","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADM11\/CE1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability digital input module designed for the Yokogawa Electric Corporation CENTUM VP and CENTUM CS 3000 platforms.\u003c\/p\u003e\n\u003cp\u003eThis module is engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediscrete signal acquisition\u003c\/strong\u003e, converting field-side dry or wet contact signals into logic-level data for the DCS processor. It is typically used to monitor:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLimit switch positions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotor run\/stop and fault status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperator pushbuttons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety interlocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“\/CE1”\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix denotes compliance with specific EMC and interface standards, making it suitable for installations requiring CE marking and enhanced electromagnetic immunity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003eADM11\/CE1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003e16-channel discrete contact inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eDry contact or voltage-sensing (wet) contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Pulse Width\u003c\/td\u003e\n\u003ctd\u003e≤ 20 ms detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation (field-to-system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.5 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.113 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEquipment Status Monitoring\u003c\/strong\u003e\u003cbr\u003eTracks operational and fault states of pumps, compressors, conveyors, and auxiliary systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Interlock Systems\u003c\/strong\u003e\u003cbr\u003eMonitors valve position limit switches, safety gates, and ESD permissive signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSequential \u0026amp; Batch Control\u003c\/strong\u003e\u003cbr\u003eProvides discrete event triggers for automated startup, shutdown, and batch processing sequences.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ADM11\/CE1 require external field power?\u003c\/strong\u003e\u003cbr\u003eYes. A 24 V DC field power supply is typically required to energize (wet) the contacts so the module can detect current flow when the circuit closes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the \/CE1 variant?\u003c\/strong\u003e\u003cbr\u003eThe \/CE1 version is commonly specified for CE-marked projects or installations requiring enhanced electromagnetic compatibility (EMC), ensuring stable performance in high-EMI environments such as power plants and refineries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module detect high-speed pulse inputs?\u003c\/strong\u003e\u003cbr\u003eNo. The ADM11\/CE1 is intended for status monitoring, not high-speed pulse counting. For turbine flow meters or encoder applications, a dedicated pulse module such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAP849-S50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis recommended.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51818393207096,"sku":"ADM11\/CE1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADM11CE12.jpg?v=1771898191","url":"https:\/\/www.automodulexpert.com\/products\/yokogawa-adm11-ce1-contact-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}