{"product_id":"yokogawa-adv151-p13-centum-vp-fio-digital-input-module","title":"Yokogawa ADV151-P13 CENTUM VP FIO Digital Input Module","description":"\u003ch2\u003eYokogawa ADV151-P13 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV151-P13\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for discrete signal acquisition within Yokogawa CENTUM VP and CENTUM CS 3000 systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FIO Node Chassis Slot Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W (500 mA @ 5 VDC internal backplane draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32 digital inputs (isolated per 16-channel group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (18 to 26.4 VDC ON state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eESB\/ER Bus Node Units (ANB10, ANB11, ANR10), FCU (AFV30\/40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 VAC (signal-to-system), 500 VAC (between commons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; 4-20 mA HART Signal Coexistence\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa ADV151-P13 incorporates optical isolation rated up to 2000 VAC between field terminal loops and internal processing logic, protecting central processors against high-voltage surges. Group isolation rated at 500 VAC prevents inter-channel crosstalk across its 32 input points. By decoupling discrete 24 VDC switching noise from sensitive backplane buses, the module allows digital status monitoring and SOE event logging to operate alongside analog instrument channels without corrupting 4-20 mA HART loop protocol signals sharing the same node rack.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the \"P13\" suffix designation affect the environmental and physical capabilities of the ADV151 module?\u003c\/p\u003e\n\u003cp\u003eA: The \"P\" indicates pushbutton input enablement with SOE capture capabilities, the \"1\" signifies standard architectural mounting, and the \"3\" designates compliance with ISA G3 corrosive gas environments alongside an expanded operating temperature range of -20 to +70 deg C.\u003c\/p\u003e\n\u003cp\u003eQ: Can two ADV151-P13 modules be configured for dual-redundant digital signal acquisition?\u003c\/p\u003e\n\u003cp\u003eA: Yes, dual-redundant operation is supported when installing two units in adjacent slots of a compatible ESB or ER bus node unit, permitting real-time logic synchronization without signal interruption during single-module maintenance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFirst, turn off node supply feeds before inserting the module along slot guide rails, torqueing top and bottom chassis lock screws to ensure ground connection with the cabinet busbar. Attach field wiring using dedicated pressure clamp terminals or AKB331 cable assemblies, verifying that all discrete 24 VDC signal wiring maintains unified polarity across each 16-channel common group. Second, route signal cables separately from high-voltage AC lines, grounding the cable shield braid directly to the cabinet protective earth (PE) bus clamp to block external electrical interference. Finally, confirm clearance around the node rack for unhindered natural convection to maintain enclosure temperatures within the specified -20 to +70 deg C envelope.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51179251925304,"sku":"ADV151-P13","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADV151-P13.jpg?v=1759128952","url":"https:\/\/www.automodulexpert.com\/products\/yokogawa-adv151-p13-centum-vp-fio-digital-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}