{"product_id":"yokogawa-aea4d-00-s1-analog-terminal-board","title":"Yokogawa AEA4D-00 S1 Analog Terminal Board","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAEA4D-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density analog terminal board designed to provide robust signal connectivity for Yokogawa control systems. Engineered for precision and reliability, this board supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 channels of analog input or output\u003c\/strong\u003e, making it suitable for complex industrial automation environments.\u003c\/p\u003e\n\u003cp\u003eIts architecture is optimized for both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle and dual-redundant configurations\u003c\/strong\u003e, which makes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAEA4D-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ea critical component in high-availability process control systems. The board ensures clean signal transfer between field instrumentation and the DCS backplane. With rugged industrial construction and secure screw-terminal connections, it minimizes contact resistance and signal degradation, maintaining high signal fidelity for critical analog loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003eAEA4D-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Function\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\/Output Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eCompatible with single and dual-redundant module configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion Type\u003c\/td\u003e\n\u003ctd\u003eStandard industrial version (Suffix: -00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eScrew-type field wiring terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Integration\u003c\/td\u003e\n\u003ctd\u003eCompatible with Yokogawa analog I\/O architectures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eCabinet-mounted terminal board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Signal Consolidation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCentralizes field wiring for transmitters such as pressure, temperature, and flow sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Loop Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports physical wiring for dual-redundant analog control loops, improving system availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Instrumentation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for refineries, petrochemical plants, power generation facilities, and other large-scale process industries requiring reliable I\/O density.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Cabinet Organization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides structured wiring interfaces to simplify installation and maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the AEA4D-00 support both input and output signals?\u003c\/strong\u003e\u003cbr\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAEA4D-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be used for both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input and analog output signals\u003c\/strong\u003e, depending on the specific analog I\/O module connected within the Yokogawa control system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this terminal board compatible with legacy analog modules?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAEA4D-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to maintain compatibility with many\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandard Yokogawa analog I\/O series modules\u003c\/strong\u003e. However, it is recommended to verify the module pin-out and electrical specifications to ensure proper mechanical and electrical matching.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51859382501688,"sku":"AEA4D-00 S1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AEA4D-00_S1.jpg?v=1772762249","url":"https:\/\/www.automodulexpert.com\/products\/yokogawa-aea4d-00-s1-analog-terminal-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}