{"product_id":"yokogawa-aip504-11-v-net-coupler-module-centum-dcs","title":"Yokogawa AIP504-11 V-NET Coupler Module CENTUM DCS","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe AIP504-11 is a specialized V-NET coupler module designed for the Yokogawa Electric Corporation\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM distributed control systems (DCS)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts primary function is to facilitate high-speed data transmission between Field Control Stations (FCS) and Human Interface Stations (HIS) over the proprietary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eV-NET communication bus\u003c\/strong\u003e. Acting as a communication bridge, the module ensures signal integrity, synchronization, and deterministic data exchange across the control network architecture.\u003c\/p\u003e\n\u003cp\u003eWith its compact form factor and optical isolation design, the AIP504-11 is essential for maintaining stable real-time communications in complex process environments where continuous plant monitoring and control are critical.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eAIP504-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eV-NET Interface \/ Coupler Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation between nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003eCoaxial cable connection (V-NET backbone)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Slot\u003c\/td\u003e\n\u003ctd\u003eDedicated communication slot in card cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eBackplane powered (5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e102 mm (H) × 51 mm (W) × 152 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 2.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eNetwork Implementation\u003c\/h3\u003e\n\u003cp\u003eThe AIP504-11 is typically installed within the card file of a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Station (FCS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor bus converter unit in legacy CENTUM systems. It couples data packets onto the coaxial V-NET backbone, which serves as the primary communication artery for systems such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCENTUM CS 3000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCENTUM XL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn redundant network architectures, two AIP504-11 modules are deployed to ensure communication continuity in the event of a single module failure, thereby preventing unexpected network downtime.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the AIP504-11 be used with Vnet\/IP systems?\u003c\/strong\u003e\u003cbr\u003eNo. The AIP504-11 is specifically designed for the coaxial-based V-NET protocol. For modern Vnet\/IP networks, interface modules such as the VI451 or VI461 are required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle signal interference?\u003c\/strong\u003e\u003cbr\u003eThe AIP504-11 incorporates high-performance optical isolation and transformer coupling to protect internal system logic from surges, noise, or grounding issues present on external coaxial V-NET cabling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the -11 suffix and other versions?\u003c\/strong\u003e\u003cbr\u003eThe “-11” suffix generally indicates a hardware revision or internal component update, providing improved thermal stability and long-term reliability compared to earlier releases.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51854359134520,"sku":"AIP504-11","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AIP504-112.jpg?v=1772675159","url":"https:\/\/www.automodulexpert.com\/products\/yokogawa-aip504-11-v-net-coupler-module-centum-dcs","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}