{"product_id":"yokogawa-nfai143-h50-ccc01-analog-input-module","title":"Yokogawa NFAI143-H50\/CCC01 Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFAI143-H50\/CCC01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analog input module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrated control system. This module serves as a critical interface for 4 to 20 mA DC field signals, providing high-density data acquisition with 16 fully isolated channels. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CCC01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix indicates the presence of a conformal coating, making the unit suitable for deployment in harsh industrial environments where corrosive gases or moisture may be present.\u003c\/p\u003e\n\u003cp\u003eBy utilizing high-voltage electrical isolation between the input terminals and the internal system circuitry, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFAI143-H50\/CCC01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures signal integrity and prevents common-mode noise from affecting the process controller. It is specifically designed for mission-critical loops where reliability and precision are non-negotiable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 channels, isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Conversion Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Refresh Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for 1 minute (Input to System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA maximum at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtective Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformal coating (\/CCC01) for G3 environmental resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModule Variants Comparison\u003c\/h3\u003e\n\u003cp\u003eWhile the standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFAI143\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandles basic 4-20 mA signals, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFAI143-H50\/CCC01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes specific enhancements:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eH50 Suffix\u003c\/strong\u003e: Denotes the standard speed version with high isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCCC01 Option\u003c\/strong\u003e: Adds a protective layer against corrosion, unlike the standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion which lacks this coating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Fully compatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI143\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAV144\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eracks depending on the specific terminal block used.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Technical Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: Is the NFAI143-H50\/CCC01 hot-swappable?\u003cbr\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: Yes, this module supports hot-swapping within a redundant or non-redundant configuration when mounted on a compatible FIO bus unit, allowing for maintenance without interrupting the control process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: What is the benefit of the CCC01 option?\u003cbr\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CCC01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesignation confirms the module is compliant with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISA S71.04 G3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandards, protecting the PCB from chemical contaminants found in refineries and paper mills.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51846924796216,"sku":"NFAI143-H50\/CCC01","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFAI143-H50CCC012.jpg?v=1772417010","url":"https:\/\/www.automodulexpert.com\/products\/yokogawa-nfai143-h50-ccc01-analog-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}