{"product_id":"yokogawa-nfdv151-p10-d5a00-digital-input-module","title":"Yokogawa NFDV151-P10\/D5A00 Digital Input Module","description":"\u003ch3\u003eTechnical Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFDV151-P10\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital input module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol systems. As part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFIO (Field Interface Option)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O family, it provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 discrete input channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor monitoring field signals such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edry contacts and voltage-free devices\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module is commonly used to capture operational status signals from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elimit switches, valve position indicators, motor feedback contacts, and safety interlocks\u003c\/strong\u003e. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFDV151-P10\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eD5A00 specialized connector interface\u003c\/strong\u003e, ensuring secure signal termination and standardized wiring within Yokogawa I\/O racks.\u003c\/p\u003e\n\u003cp\u003eManufactured with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial-grade components in Japan\u003c\/strong\u003e, the module delivers the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereliability and high availability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequired for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous process operations and safety-critical monitoring environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels (common ground, non-isolated between channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eDry contact or voltage-free contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (internal or external supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON Threshold\u003c\/td\u003e\n\u003ctd\u003e≥ 12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF Threshold\u003c\/td\u003e\n\u003ctd\u003e≤ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4 mA per channel at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e8 ms (selectable filter options available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eCompatible with dual-redundant system configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eD5A00 pressure clamp \/ interface connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V AC between input terminals and system ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e126 mm × 124 mm × 22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Use Cases\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFDV151-P10\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eautomated production lines and process plants\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto monitor discrete operational states. Typical applications include\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evalve open\/close position monitoring, pump running status, safety interlock signals, and emergency stop circuits\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThanks to its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32-channel high-density design\u003c\/strong\u003e, the module helps\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereduce cabinet space requirements\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhile maintaining reliable signal acquisition. Integration with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa FIO bus architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time data transmission\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHuman Machine Interface (HMI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand control logic for immediate operator visibility and control system response.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProduct Comparison\u003c\/h3\u003e\n\u003cp\u003eCompared with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFDV151-P11 variant\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFDV151-P10\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandard industrial environmental conditions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhile maintaining the same\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32-channel digital input functionality\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/D5A00 suffix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eidentifies the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especific terminal interface configuration\u003c\/strong\u003e, ensuring compatibility with the corresponding\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eD5A00 terminal board or connector system\u003c\/strong\u003e. This designation is particularly important during\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtrol cabinet design and wiring planning\u003c\/strong\u003e, helping engineers maintain\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econsistent hardware integration across Yokogawa I\/O nodes\u003c\/strong\u003e.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51865016140088,"sku":"NFDV151-P10\/D5A00","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFDV151-P10D5A00.jpg?v=1773020857","url":"https:\/\/www.automodulexpert.com\/products\/yokogawa-nfdv151-p10-d5a00-digital-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}