{"product_id":"yokogawa-sec402-51-vnet-ip-bus-coupler-module-centum-vp","title":"YOKOGAWA SEC402-51 Vnet\/IP Bus Coupler Module CENTUM VP","description":"\u003ch2\u003eYOKOGAWA SEC402-51 Bus Coupler Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA SEC402-51\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSEC402\u003c\/strong\u003e Bus Coupler Module, operates as a dedicated hardware component for high-speed field control unit interfacing within Vnet\/IP network architectures. The card executes real-time frame buffering and signal level matching between local subsystem backplanes and main plant communications rings. By maintaining deterministic token timing and converting internal data protocols to physical line signals, the module prevents packet collision and minimizes scan latency across distributed DCS stations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSEC402-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa slot enclosure size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Protocol\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP Network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eEthernet RJ45 and Coaxial BNC Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Task\u003c\/td\u003e\n\u003ctd\u003eField Control Unit Bus Coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFieldbus Protocols \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eDesigned for process control deployments, the SEC402-51 incorporates channel-to-channel isolation circuits to prevent circulating ground currents from disturbing communication integrity. The module handles 4-20 mA HART loop protocol translation at the controller gateway while facilitating direct pass-through for FOUNDATION Fieldbus segments. Onboard cold junction compensation (CJC) algorithms and galvanic signal isolation suppress high-frequency line interference, maintaining data frame stability across extended fieldbus links.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What physical network media connections does the SEC402-51 support for bus coupling?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates both an Ethernet RJ45 port and a coaxial BNC connector, allowing direct connection to standard coaxial network segments or Ethernet-based Vnet\/IP bus backbones.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane power supply considerations for the SEC402-51?\u003c\/p\u003e\n\u003cp\u003eA: The module draws power directly from the internal subrack power rail, operating with a maximum power dissipation of 3 W, which minimizes total thermal loading inside the control enclosure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInsert the SEC402-51 firmly into its assigned subrack slot prior to applying power to the local node. Fasten all top and bottom module retaining screws to ensure proper grounding through the subrack frame and to prevent accidental physical displacement.\u003c\/p\u003e\n\u003cp\u003eRoute coaxial lines and Ethernet cables in grounded metal conduits isolated from high-voltage AC lines, motor leads, and variable frequency drive wiring. Terminate cable shields at a single ground reference point to eliminate ground loops. Respect the minimum allowable cable bend radius during routing to prevent impedance mismatches and physical degradation of the signal conductors.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51178815717688,"sku":"SEC402-51","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/SCP461-51_S22.jpg?v=1759042730","url":"https:\/\/www.automodulexpert.com\/products\/yokogawa-sec402-51-vnet-ip-bus-coupler-module-centum-vp","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}