{"product_id":"yokogawa-ssc60d-f2521-duplexed-safety-control-unit","title":"Yokogawa SSC60D-F2521 Duplexed Safety Control Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSC60D-F2521\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents the core processing intelligence of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety instrumented system (SIS). This duplexed safety control unit is engineered to perform high-speed safety logic execution while maintaining a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Safety Integrity Level 3) rating in a single-unit configuration. Unlike standard control units, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSC60D-F2521\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a redundant internal architecture to ensure that a single component failure does not lead to a system trip or loss of protection.\u003c\/p\u003e\n\u003cp\u003eOperating over the high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication backbone, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSC60D-F2521\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides seamless integration with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control systems. This rack-mountable unit is designed for continuous operation in mission-critical environments such as emergency shutdown (ESD) systems, fire and gas (F\u0026amp;G) monitoring, and burner management systems (BMS).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Redundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-redundant (Duplexed) internal CPU architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP (Dual-redundant Ethernet-based protocol)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Gbps (Full duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Execution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCertified for IEC 61508 SIL 3 applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch rack-mountable (13U height typically required for full assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC or 220-240 V AC (Depends on power supply module selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports up to 9 racks of I\/O modules per unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Functional Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault Tolerance\u003c\/strong\u003e: The duplexed nature of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSC60D-F2521\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for online module replacement and firmware updates without compromising the safety function of the plant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Integration\u003c\/strong\u003e: By utilizing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP\u003c\/strong\u003e, the unit achieves high-bandwidth data exchange with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHuman Interface Stations (HIS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor real-time diagnostics and sequence-of-events (SOE) recording.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Footprint\u003c\/strong\u003e: Despite its high processing power, the rack-mountable design allows for high-density installation in standard marshalling cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: Does the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSC60D-F2521\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequire a separate safety license?\u003cbr\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: Yes, the unit requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elogic execution license. The hardware itself serves as the execution environment for the safety programs developed in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCS Builder\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion\u003c\/strong\u003e: Can this unit be used for non-safety control tasks?\u003cbr\u003e\u003cstrong\u003eAnswer\u003c\/strong\u003e: While technically capable of complex logic, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSC60D-F2521\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically certified and intended for safety-critical functions. Using it for general process control is possible but usually not cost-effective compared to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51846942884152,"sku":"SSC60D-F2521","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/SSC60D-F2521.jpg?v=1772417010","url":"https:\/\/www.automodulexpert.com\/products\/yokogawa-ssc60d-f2521-duplexed-safety-control-unit","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}