{"product_id":"yokogawa-vi702-s1-vnet-ip-interface-card","title":"Yokogawa VI702 S1 Vnet\/IP Interface Card","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVI702 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance communication interface module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrated production control system. It provides a direct hardware interface between an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHMI (HIS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOpen Communication Server\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP real-time control network\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUsing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGigabit Ethernet technology\u003c\/strong\u003e, the VI702 S1 (Part Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVI702-S1\u003c\/strong\u003e) delivers deterministic, low-latency data transmission, making it well suited for large-scale, mission-critical industrial automation systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications \u0026amp; Environmental Data\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 compliant Vnet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e1 Gbps, Full Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant 1000BASE-T (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Connection\u003c\/td\u003e\n\u003ctd\u003ePCI Express (PCIe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 1.0 A @ 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e5 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eCompact, low-profile design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass\u003c\/td\u003e\n\u003ctd\u003e1.3kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, KC, CSA compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe VI702 S1 is typically installed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtrol room HIS stations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequiring a dedicated and reliable interface to the Vnet\/IP plant network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical uses include:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time process data visualization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperator monitoring and control via HMI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem configuration and engineering tasks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork diagnostics over the Vnet\/IP backbone\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the VI702 S1 and earlier interface cards?\u003c\/strong\u003e\u003cbr\u003eThe VI702 S1 is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP over Gigabit Ethernet\u003c\/strong\u003e, offering substantially higher throughput and lower latency than legacy Vnet interfaces, while preserving the reliability required for critical DCS operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the VI702 S1 support network redundancy?\u003c\/strong\u003e\u003cbr\u003eYes. The module includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual onboard Ethernet ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat fully support the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP dual-redundant architecture\u003c\/strong\u003e, ensuring continuous communication in the event of a cable, port, or switch failure.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51761380557112,"sku":"VI702-S1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/VI702-S12.jpg?v=1770688056","url":"https:\/\/www.automodulexpert.com\/products\/yokogawa-vi702-s1-vnet-ip-interface-card","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}