{"product_id":"aat141-s50-yokogawa-tc-mv-isolated-input-module","title":"Módulo de Entrada Isolada TC\/mV AAT141-S50 Yokogawa","description":"\u003ch2\u003e\u003cstrong\u003eDescrição do Produto\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAT141-S50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emódulo de entrada analógica de 16 canais de alta precisão\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esistemas Yokogawa CENTUM VP e ProSafe-RS\u003c\/strong\u003e. Projetado para\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ea aquisição de sinais de baixo nível\u003c\/strong\u003e, suporta\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etermopares (TC) e entradas em milivolts (mV)\u003c\/strong\u003e, com completa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eisolação entre canais\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara evitar loops de terra e interferência em modo comum.\u003c\/p\u003e\n\u003cp\u003eCada canal é\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econfigurável de forma independente\u003c\/strong\u003e, permitindo a atribuição flexível do tipo de sensor ou faixa de entrada. O módulo possui\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edetecção de falha por circuito aberto\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara alertar o sistema de controle imediatamente em caso de sensor aberto. Sua\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eisolação robusta (1500 V CA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ealta resistência de entrada\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efazem dele uma escolha confiável para\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emonitoramento de temperatura de alta fidelidade e longo prazo\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eem aplicações industriais exigentes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eEspecificações Técnicas\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParâmetro\u003c\/th\u003e\n\u003cth\u003eEspecificação\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanais de Entrada\u003c\/td\u003e\n\u003ctd\u003e16 canais isolados\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFaixas de Entrada em Milivolts\u003c\/td\u003e\n\u003ctd\u003e-100 a 150 mV; -20 a 80 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisão do Sinal\u003c\/td\u003e\n\u003ctd\u003eTC: ±30 μV; mV: ±30–80 μV (dependente da faixa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolução da Conversão A\/D\u003c\/td\u003e\n\u003ctd\u003eAlta precisão, ciclo de atualização de 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistência de Entrada\u003c\/td\u003e\n\u003ctd\u003e≥ 2 MΩ (ativa durante Ligado e Desligado)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensão de Entrada Permitida\u003c\/td\u003e\n\u003ctd\u003e±5 V CC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClassificação de Isolamento\u003c\/td\u003e\n\u003ctd\u003e1500 V CA entre entradas e lógica do sistema (1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetecção de Falha por Circuito Aberto\u003c\/td\u003e\n\u003ctd\u003eConfiguração para escala alta\/baixa; tempo de detecção de 60 segundos\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequisitos de Energia\u003c\/td\u003e\n\u003ctd\u003eMáx 450 mA a 5 V CC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSufixo \/ Revisão\u003c\/td\u003e\n\u003ctd\u003e-S50 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e0,2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eAplicação Industrial\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAT141-S50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé amplamente utilizado em:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGeração de energia\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(monitoramento de temperatura de fornos e caldeiras)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFundição de metais\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFabricação de vidro\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReatores químicos\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eque exigem monitoramento isolado e de alta densidade de temperatura\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSeus\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 canais isolados\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egarantem que múltiplos sensores de termopar ou milivolts não interfiram entre si, mantendo a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintegridade do sinal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara o controle crítico do processo.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003ePerguntas Frequentes\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePosso misturar diferentes tipos de termopares em um único módulo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSim. Cada canal pode ser configurado individualmente via software para um tipo diferente de termopar ou faixa de milivolts, permitindo arranjos flexíveis e diversos de sensores em um único módulo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eO que acontece se um fio do sensor se romper?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edetecção programável de falha por circuito aberto\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edo módulo pode ser ajustada para levar o sinal a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eescala máxima para cima ou para baixo\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eao detectar um circuito aberto. Isso permite que a lógica do sistema acione imediatamente alarmes ou inicie um desligamento seguro.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51707172094264,"sku":"AAT141-S50","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AAT141-S50.jpg?v=1770256781","url":"https:\/\/www.automodulexpert.com\/pt\/products\/aat141-s50-yokogawa-tc-mv-isolated-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}