{"product_id":"duplexed-field-control-unit-yokogawa-afv30d-a41152","title":"Unidade de Controle de Campo Duplexada Yokogawa AFV30D-A41152","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFV30D-A41152\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé uma\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUnidade de Controle de Campo (FCU) de alto nível\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprojetada para o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP DCS\u003c\/strong\u003e. Oferece\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecapacidades de automação industrial crítica para missão\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecom\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundância sem tempo de inatividade\u003c\/strong\u003e. Esta unidade\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eduplexada\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epossui\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emódulos de processador duplos\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efontes de alimentação\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara operação contínua durante manutenção ou falha de hardware. Seu design compacto\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epara montagem em rack de 19 polegadas\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé ideal para integração de alta densidade em salas de controle.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eRecurso\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArquitetura do Processador\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eProcessador RISC VR5532\u003c\/strong\u003e, 350 MHz para execução rápida de controle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemória do Sistema\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e128 MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRAM para lógica de controle em larga escala e bancos de dados da planta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguração de Redundância\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompletamente duplexada, com dois processadores\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee sincronização ativa\/em espera\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComunicações de Rede\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterfaces\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eduplamente redundantes (1 Gbps) para sincronização de dados em toda a planta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacidade de Expansão de E\/S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGerencia até\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e13 unidades de nó\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(local\/remoto) via barramento\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFIO\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContatos de Alarme Externos\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e2 terminais de contato READY\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(30V DC, 0,3A máx.) para sinais de alarme\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProteção de Memória\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eBateria reserva de 72 horas\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara retenção de dados na RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface de Diagnóstico\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterface opcional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/HKU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara monitoramento ambiental (temperatura, ventiladores, segurança)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstalação Física\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMontagem em rack de 19 polegadas\u003c\/strong\u003e, altura 5U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensões (A×L×P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e221 mm (A) × 482,6 mm (L) × 440 mm (P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e8,5 kg\u003c\/strong\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eCenários de Aplicação\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFV30D-A41152\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé ideal para ambientes de alta disponibilidade, incluindo:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessamento de Hidrocarbonetos\u003c\/strong\u003e: Loops PID complexos para refinarias e terminais de GNL.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGeração de Energia\u003c\/strong\u003e: Controle sequencial de alta velocidade para gerenciamento de turbinas e caldeiras.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFabricação Farmacêutica\u003c\/strong\u003e: Controle em batelada e conformidade regulatória com retenção confiável de dados.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003ePerguntas Frequentes sobre Confiabilidade\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComo a redundância \"Duplexada\" difere do backup padrão?\u003c\/strong\u003e\u003cbr\u003eEm um\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esistema duplexado\u003c\/strong\u003e, ambos os\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocessadores CP461\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efuncionam em paralelo. O\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocessador em espera\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé continuamente atualizado com a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ememória do processador ativo\u003c\/strong\u003e. Se o primário falhar, o sistema realiza uma\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etransferência sem interrupção\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eem milissegundos, garantindo que não haja perda de controle sobre processos físicos como válvulas e motores.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO ambiente físico do gabinete da FCU pode ser monitorado?\u003c\/strong\u003e\u003cbr\u003eSim, a interface\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopcional \/HKU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epermite monitorar a saúde do gabinete, incluindo o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estatus do ventilador de resfriamento\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etemperatura\u003c\/strong\u003e e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esegurança do invólucro\u003c\/strong\u003e. Esses dados podem ser enviados diretamente para a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEstação de Interface Humana (HIS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara manutenção preditiva antes que qualquer problema térmico cause desligamentos do sistema.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51907085271352,"sku":"AFV30D-S41152","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AFV10D-S41101_S21.jpg?v=1773798210","url":"https:\/\/www.automodulexpert.com\/pt\/products\/duplexed-field-control-unit-yokogawa-afv30d-a41152","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}